Home › Power Source / Network › 1GD-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.08
RM27T0E _57 Power Source / Network _053727 1GD-FTV BATTERY / CHARGING _0261025 CHARGING SYSTEM G

1GD-FTV BATTERY / CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 28800 1.CHECK BATTERY CONDITION

NOTICE:

If the battery is weak or if the engine is difficult to start, perform the following procedures.


a.

Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.


b.

Check the electrolyte quantity of each cell.

i.

For maintenance-free batteries:

·

If the electrolyte quantity is below the lower line, replace the battery.

·

If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine. If the voltage is below 9.6 V, recharge or replace the battery.

HINT:

Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).




ii.

For non-maintenance-free batteries:

·

If the electrolyte quantity is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte's specific gravity.

Standard specific gravity:

1.25 to 1.29 at 20°C (68°F)


·

If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine. If the voltage is below 9.6 V, recharge or replace the battery.

HINT:

Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).





c.

Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This removes the surface charge from the battery.


d.

Measure the battery voltage between the negative (-) and positive (+) terminals of the battery.

Standard voltage:

12.5 to 12.9 V at 20°C (68°F)


If the voltage is less than the specification, recharge the battery.


Hide 2.REPLACE BATTERY (w/ Stop And Start System)

a.

Replace the battery.

NOTICE:

Use a genuine battery specifically designed for use with the stop and start system or a battery with equivalent specification to a genuine battery. If an unsupported battery is used, stop and start system functions may be restricted to protect the battery.

Also, battery performance may decrease and the engine may not be able to restart.

Battery Type
T-115 type or equivalent to a genuine battery



Hide 3.INSPECT BATTERY TERMINAL AND FUSE

a.

Check that the battery terminals are not loose or corroded.

Torque:
Positive (+) battery terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) battery terminal : 5.4 N*m (55 kgf*cm, 4.8 in.*lbf)

If the terminals are corroded, clean the terminals.


b.

Measure the resistance of the and fuses.

Standard resistance:

Below 1 Ω


If the result is not as specified, replace the fuses.


Hide 5.INSPECT GENERATOR WIRING

a.

Visually check the generator wiring.

i.

Check that the wiring is in good condition.



Hide 6.CHECK FOR ABNORMAL NOISES

a.

Listen for abnormal noises from the generator.

i.

Check that no abnormal noises are heard from the generator while the engine is running.



Hide 7.INSPECT CHARGE WARNING LIGHT CIRCUIT

a.

Turn the ignition switch to ON. Check that the charge warning light comes on.


b.

Start the engine and check that the light goes off.

If the light does not operate as specified, troubleshoot the charge warning light circuit.


Hide 8.INSPECT CHARGING CIRCUIT WITHOUT LOAD

a.

Connect a voltmeter and ammeter to the charging circuit as follows.

i.
A125200E13
2.292,1.917 2.521,1 2.521,1 2.667,1 false 2.604,2.156 2.729,2.49 2.729,2.49 2.844,2.49 false 0.521,2.25 0.365,2.01 0.365,2.01 0.26,2.01 false 0.052,1.927 0.229,2.094 0.177,0.167 10 false *1 2.854,2.396 3.042,2.563 0.188,0.167 10 false *3 2.708,0.917 2.875,1.083 0.167,0.167 10 false *2

Disconnect the wire from terminal B of the generator, and then connect it to the negative (-) lead of an ammeter.

Text in Illustration
*1 Battery
*2 Generator
*a Terminal B


ii.

Connect the positive (+) lead of the ammeter to terminal B of the generator.


iii.

Connect the positive (+) lead of a voltmeter to the positive (+) terminal of the battery.


iv.

Ground the negative (-) lead of the voltmeter.



b.

Check the charging circuit.

i.

Maintain the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.

Standard current:

10 A or higher


Standard voltage:

13.2 to 14.35 V


If the voltmeter reading is higher than the standard voltage, replace the generator assembly.

HINT:

If the battery is not fully charged, the ammeter reading will sometimes be higher than the standard current.




Hide 9.INSPECT CHARGING CIRCUIT WITH LOAD

a.

With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the HI position.


b.

Check the reading on the ammeter.

Standard current:

30 A or higher


If the ammeter reading is below the standard current, repair the generator.

HINT:

If the battery is fully charged, the indication will sometimes be less than the standard current. If this is the case, add more electrical load (operate the wipers, rear window defogger, etc.) and check the reading on the ammeter again.



Hide 10.INSPECT CHARGING SYSTEM

a.

w/o Stop And Start System:

Check the harness and connector.

i.

Disconnect the C152 ECM connector.


ii.

Disconnect the C157 generator assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C152-7(LIN) - C157-2(LIN) Always Below 1 Ω
C152-7(LIN) - C157-2(LIN) - Body ground engine switch off
(while LIN communication is stopped)
10 kΩ or higher

If the result is not as specified, repair or replace the harness or connector.



b.

w/ Stop And Start System:

Check the harness and connector.

i.

Disconnect the C152 ECM connector.


ii.

Disconnect the C157 generator assembly connector.


iii.

Disconnect the A95 battery state sensor assembly connector.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C152-7(LIN) - C157-2(LIN) Always Below 1 Ω
C152-7(LIN) - C157-2(LIN) - Body ground engine switch off
(while LIN communication is stopped)
10 kΩ or higher
C152-7(LIN) - A95-2(LIN) Always Below 1 Ω
C152-7(LIN) - A95-2(LIN) - Body ground engine switch off
(while LIN communication is stopped)
10 kΩ or higher

If the result is not as specified, repair or replace the harness or connector.