Home › Power Source / Network › 1GD-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.08
RM27T0E _57 Power Source / Network _053727 1GD-FTV BATTERY / CHARGING _0261025 CHARGING SYSTEM U

1GD-FTV BATTERY / CHARGING  CHARGING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / Engine / Data List.


g.

According to the display on the GTS, read the Data List.

HINT:

Normal Condition: If no idling conditions are specified, the shift lever should be in N or P, and the A/C switch and all accessory switches should be off.


Powertrain > Engine and Transmission > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Voltage Battery voltage Min.: 0.0 V
Max.: 65.5 V
11 to 14 V (Idling) If the result is not as specified, abnormal battery voltage is suspected.
Battery Sensor Voltage Battery sensor voltage Min.: 0.000 V
Max.: 79.998 V
11 to 14 V (Idling) -
Alternate Duty Ratio Alternator generation duty ratio Min.: 0%
Max.: 100%
·

No electrical load at idling: 20 to 60%

·

High electrical load at idling: 100%


·

This is outputs the alternator generation duty and is used to determine the electrical load.

·

Can be used to determine whether a higher-than-normal injection volume at idle, etc. is due to electrical loading or from some other source. For example, when the duty is not high but the idling injection volume is high, there is injector volume degradation or high engine friction.

·

Can be used for judging whether or not a malfunctioning component in the electrical system is generating continual generation requests (e.g., battery deterioration is causing an unending full recharge request, etc.). Regardless of whether or not an auxiliary device like the A/C or heater is active, if the alternator duty is always at the maximum value, there is an electrical system abnormality, like battery deterioration.


Battery Current Battery current Min.: -125.0 A
Max.: 124.9 A
Changes according to alternator output (While driving after engine warmed up) If the result is not as specified, a malfunction of LIN communication is suspected.
Battery Temperature Battery temperature Min.: -40.0°C (-40°F)
Max.: 6513.5°C (11756°F)
Changes according to actual temperature (While driving after engine warmed up) If the result is not as specified, a malfunction of LIN communication is suspected.
Alternator Output Duty Ratio Generator output duty Min.: 0.0%
Max.: 399.9%
Changes in accordance with the generator output If the result is not as specified, a malfunction of the charging control system is suspected.
Alternator Voltage - Non Active Test Requested voltage when regulator forced drive is not executed Min.: 0.000 V
Max.: 79.998 V
12.5 to 14.8 V (After engine start (Varies with battery temperature or driving conditions)) Active Test support data
Voltage of Alternator Requested voltage when regulator forced drive is executed Min.: 0.00 V
Max.: 79.99 V
Required instruction voltage value when the Active Test "Control the Voltage of Alternator" is executed (10.6 to 16.0 V): After engine started Malfunction of the charging control system can be the cause of malfunction
Previous Trip Alternator Max Output Time Generator maximum generating time during previous drive Min.: 0 sec.
Max.: 65535sec.
- -
Initial Engine Battery Minimum Voltage Minimum battery voltage at engine start Min.: 0.0 V
Max.: 25.5 V
- -
Previous Trip Charge Control Time Charging control time during previous drive Min.: 0 sec.
Max.: 65535 sec.
- -
Previous Trip Average Battery Temperature Battery average temperature during previous drive Min.: -40°C (-40°F)
Max.: 215°C (419°F)
- -
Battery Charging Rate Accuracy Battery charging rate accuracy Low/Middle/High/Disable - -
Battery Status of Full Charge Battery status of full charge Min.: 0 Ah
Max.: 127.5 Ah
- -
Battery Dark Current battery dark current Min.: 0 m
Max.: 65535 mA
- -
Battery Sensor Sleep Time Battery sensor sleep time Min.: 0 day
Max.: 255 day
- -


ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and Transmission / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Powertrain > Engine and Transmission > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Voltage of Alternator Requested output voltage of generator regulator during forced activation 12.5 to 14.8 V Test is possible after engine start