2011-2013 Land Cruiser · Service Manual Drivetrain

INSPECTION

Inspection · Vehicles built from Sep 2011


INSPECT SHIFT SOLENOID VALVE SL1

C151311E15
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 1
    2. Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE S1

C160563E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S1 connector
    2. Battery negative (-) → Shift solenoid valve S1 body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE S2

C160564E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S2 connector
    2. Battery negative (-) → Shift solenoid valve S2 body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE S3

C160563E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S3 connector
    2. Battery negative (-) → Shift solenoid valve S3 body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE S4

C123198E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S4 connector
    2. Battery negative (-) → Shift solenoid valve S4 body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL2

C151311E13
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 1
    2. Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SR

C160565E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve SR connector terminal - Shift solenoid valve SR body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve SR connector
    2. Battery negative (-) → Shift solenoid valve SR body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLT

C162477E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLU

C162477E04
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.

← DISASSEMBLY (from Sep 2011)REASSEMBLY (from Sep 2011) →