INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT AIR FUEL RATIO SENSOR |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (HA1A) - 2 (+B)
(for Bank 1)
20°C (68°F)
1.8 to 3.4 Ω
1 (HA2A) - 2 (+B)
(for Bank 2)
If the result is not as specified, replace the sensor.Text in Illustration *A
for Bank 1
*B
for Bank 2
*a
Component without harness connected
(Air Fuel Ratio Sensor)