2011-2013 Land Cruiser · Service Manual Drivetrain

P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

Diagnostic trouble codes · Vehicles built from Jan 2012

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

C261119E01
The shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the current of the SLT solenoid valve to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.
DTC Code
DTC Detection Condition
Trouble Area
P2716
An open or short is detected in the shift solenoid valve SLT circuit for 1 sec. or more while driving (1 trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C219459E09

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)

  1. C214326E66
    Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    14 (SLT+) - 6 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    14 (SLT+) - Body ground
    Always
    10 kΩ or higher
    6 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. C219456E81
    Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C45-9 (SLT+) - C45-8 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C45-9 (SLT+) - Body ground
    Always
    10 kΩ or higher
    C45-8 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE SLT

  1. C209928E05
    Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SLT)


NG
REPLACE SHIFT SOLENOID VALVE SLT (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (Sep 2011 – Dec 2011)P2740 Transmission Fluid Temperature Sensor "B" Circuit (+ P2742, P2743) (Sep 2011 – Dec 2011) →