Pattern Select Switch Power Mode Circuit
Circuit diagnosis · Vehicles built from Jan 2012
DESCRIPTION
The ECM memory contains the programs for the normal and power shift patterns and lock-up pattern.By following the programs corresponding to the signals from the pattern select switch, the park/neutral position switch and other various sensors, the ECM switches the solenoid valves on and off, and controls the transmission gear change and the lock-up clutch operation.
WIRING DIAGRAM


INSPECTION PROCEDURE
When the pattern select (PWR) switch is pushed, switch contact is made and power mode is selected. To cancel power mode, push the pattern select (PWR) switch once again.| 1. INSPECT PATTERN SELECT (PWR) SWITCH |
Remove the suspension control switch (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
w/ CRAWL Tester Connection
Switch Condition
Specified Condition
3 (P) - 16 (E)
Pattern select (PWR) switch on
Below 1 Ω
3 (P) - 16 (E)
Pattern select (PWR) switch off
10 kΩ or higher
w/o CRAWL Tester Connection
Switch Condition
Specified Condition
16 (P) - 20 (E)
Pattern select (PWR) switch on
Below 1 Ω
16 (P) - 20 (E)
Pattern select (PWR) switch off
10 kΩ or higher
Text in Illustration A
w/ CRAWL
B
w/o CRAWL
*a
Component without harness connected
(Suspension Control Switch)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (PATTERN SELECT (PWR) SWITCH - BODY GROUND) |
Disconnect the suspension control switch connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
w/ CRAWL Tester Connection
Condition
Specified Condition
V4-16 (E) - Body ground
Always
Below 1 Ω
w/o CRAWL Tester Connection
Condition
Specified Condition
V4-20 (E) - Body ground
Always
Below 1 Ω
Text in Illustration A
w/ CRAWL
B
w/o CRAWL
*a
Front view of wire harness connector
(to Suspension Control Switch)
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (PATTERN SELECT (PWR) SWITCH - ECM) |
![]() ![]() |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
A38-51 (PWR) - Body ground
Pattern select (PWR) switch on
Below 1 Ω
A38-51 (PWR) - Body ground
Pattern select (PWR) switch off
10 kΩ or higher
for RHD Tester Connection
Switch Condition
Specified Condition
A52-51 (PWR) - Body ground
Pattern select (PWR) switch on
Below 1 Ω
A52-51 (PWR) - Body ground
Pattern select (PWR) switch off
10 kΩ or higher
| *1 |
for LHD |
| *2 |
for RHD |
| *a |
Front view of wire harness connector (to ECM) |
|
|
||||
| OK | ||
| ||