2011-2013 Land Cruiser · Service Manual Vehicle Interior

INSPECTION

Inspection · Vehicles built from Sep 2011


INSPECT ROOM TEMPERATURE SENSOR

E160595E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    1 - 2
    15°C (59°F)
    2.45 to 2.88 kΩ
    1 - 2
    20°C (68°F)
    1.95 to 2.30 kΩ
    1 - 2
    25°C (77°F)
    1.60 to 1.80 kΩ
    1 - 2
    30°C (86°F)
    1.28 to 1.47 kΩ
    1 - 2
    35°C (95°F)
    1.00 to 1.22 kΩ
    1 - 2
    40°C (104°F)
    0.80 to 1.00 kΩ
    1 - 2
    45°C (113°F)
    0.65 to 0.85 kΩ
    1 - 2
    50°C (122°F)
    0.50 to 0.70 kΩ
    1 - 2
    55°C (131°F)
    0.44 to 0.60 kΩ
    1 - 2
    60°C (140°F)
    0.36 to 0.50 kΩ

    If the result is not as specified, replace the room temperature sensor.

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
    1. When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (See the graph).

← REMOVAL (from Jan 2012)INSTALLATION (Sep 2011 – Dec 2011) →