ECM Power Source Circuit
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
When the engine switch is turned on (IG), battery voltage is applied to the IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil, closing the contacts of the integration relay (EFI relay) and supplying power to either terminal +B or +B2 of the ECM.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT INTEGRATION NO.1 RELAY (INTEGRATION RELAY - BODY GROUND) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
1C-1 - Body ground
Always
11 to 14 V
|
|
||||
| OK | |
| 2. INSPECT INTEGRATION NO.1 RELAY (EFI AND IG2 RELAY) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Inspect the EFI MAIN fuse and the IG2 MAIN fuse.
Remove the EFI MAIN fuse and IG2 MAIN fuse from the integration relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
EFI MAIN fuse
Always
Below 1 Ω
IG2 MAIN fuse
Always
Below 1 Ω
Inspect the EFI relay and the IG2 relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1B-4
Battery voltage is not applied to terminals 1B-2 and 1B-3
10 kΩ or higher
Battery voltage is applied to terminals 1B-2 and 1B-3
Below 1 Ω
1C-1 - 1B-8
Battery voltage is not applied to terminals 1B-7 and 1B-6
10 kΩ or higher
Battery voltage is applied to terminals 1B-7 and 1B-6
Below 1 Ω
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (+B, +B2 AND MREL CIRCUIT) |
![]() ![]() |
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A38-34 (MREL) - 1B-2
Always
Below 1 Ω
A38-2 (+B) - 1B-4
Always
Below 1 Ω
A38-1 (+B2) - 1B-4
Always
Below 1 Ω
A38-34 (MREL) or 1B-2 - Body ground
Always
10 kΩ or higher
A38-2 (+B) or 1B-4 - Body ground
Always
10 kΩ or higher
A38-1 (+B2) or 1B-4 - Body ground
Always
10 kΩ or higher
Check the harness and connectors between the integration relay and body ground.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1B-3 - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND) |
![]() ![]() |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C45-81 (E1) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 5. INSPECT ECM (IGSW VOLTAGE) |
![]() ![]() |
Disconnect the ECM connectors.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
A38-28 (IGSW) - C45-81 (E1)
Engine switch on (IG)
11 to 14 V
|
|
||||
| OK | ||
| ||
| 6. INSPECT FUSE (IGN) |
![]() ![]() |
Remove the IGN fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
IGN fuse
Always
Below 1 Ω
|
|
||||
| OK | |
| 7. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM, INTEGRATION RELAY - BODY GROUND) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1B-8 - A38-28 (IGSW)
Always
Below 1 Ω
1B-8 or A38-28 (IGSW) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 8. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - ENGINE ROOM RELAY BLOCK) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Disconnect the E2 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E2-11 (IG2D) - 1B-6
Always
Below 1 Ω
E2-11 (IG2D) or 1B-6 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 9. CHECK ENTRY AND START SYSTEM (POWER SOURCE MODE DOES NOT CHANGE) |
Check the entry and start system (Click here).
|
|
||||
| OK | ||
| ||