INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT AUTOMATIC LIGHT CONTROL SENSOR (SOLAR SENSOR) |
![]() ![]() |
Connect the battery positive (+) lead to terminal 6 and the negative (-) lead to terminal 3, then measure the according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
1 (TSL) - 3 (CLTE)
Sensor subject to electric light
0.5 V to 3.0 V
1 (TSL) - 3 (CLTE)
Sensor covered with a cloth
0.5 V or less
2 (TSR) - 3 (CLTE)
Sensor subject to electric light
0.5 V to 3.0 V
2 (TSR) - 3 (CLTE)
Sensor covered with a cloth
0.8 V or less
- HINT:
- As the inspection light is moved away from the sensor, the voltage increases.
- Use an incandescent lamp for inspection. Bring it within 30 cm (11.8 in.) of the A/C solar sensor.
- As the inspection light is moved away from the sensor, the voltage increases.