2011-2013 Land Cruiser · Service Manual Vehicle Interior

INSPECTION

Inspection · Vehicles built from Sep 2011


INSPECT SPIRAL CABLE
  1. If there are any defects as mentioned below, replace the spiral cable with a new one:
    Scratches, cracks, dents or chips on the connector or the spiral cable.

  1. B187423E02
    Check the spiral cable.

    1. Set the spiral cable to the center position (Click here).

    2. Measure the resistance between each terminal of the spiral cable according to the table below.

    3. After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise, and measure the resistance as shown. Then rotate the spiral cable 5 times counterclockwise, and measure the resistance as shown.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      E13-1 - B2
      Always
      Below 1 Ω
      E13-2 - B1
      Always
      Below 1 Ω
      E13-3 - A1
      Always
      Below 1 Ω
      E13-4 - A2
      Always
      Below 1 Ω
      E12-6 - z36-10
      Always
      Below 1 Ω
      E12-5 - z36-9
      Always
      Below 1 Ω
      E12-4 - z36-8
      Always
      Below 1 Ω
      E12-3 - z36-7
      Always
      Below 1 Ω
      E12-2 - z36-6
      Always
      Below 1 Ω
      E12-2 - z37-4
      Always
      Below 1 Ω
      E12-1 - z37-3
      Always
      Below 1 Ω
      E12-12 - z36-5
      Always
      Below 1 Ω
      E12-11 - z36-4
      Always
      Below 1 Ω
      E12-10 - z36-3
      Always
      Below 1 Ω
      E12-9 - z36-2
      Always
      Below 1 Ω
      E12-8 - z36-1
      Always
      Below 1 Ω
      E12-8 - z37-2
      Always
      Below 1 Ω
      E12-7 - z37-1
      Always
      Below 1 Ω

    4. After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise. Then while rotating the spiral cable 5 times counterclockwise, measure the resistance as shown.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      E13-1 - B2
      Always
      Below 1 Ω
      E13-2 - B1
      Always
      Below 1 Ω
      E13-3 - A1
      Always
      Below 1 Ω
      E13-4 - A2
      Always
      Below 1 Ω
      E12-6 - z36-10
      Always
      Below 1 Ω
      E12-5 - z36-9
      Always
      Below 1 Ω
      E12-4 - z36-8
      Always
      Below 1 Ω
      E12-3 - z36-7
      Always
      Below 1 Ω
      E12-2 - z36-6
      Always
      Below 1 Ω
      E12-2 - z37-4
      Always
      Below 1 Ω
      E12-1 - z37-3
      Always
      Below 1 Ω
      E12-12 - z36-5
      Always
      Below 1 Ω
      E12-11 - z36-4
      Always
      Below 1 Ω
      E12-10 - z36-3
      Always
      Below 1 Ω
      E12-9 - z36-2
      Always
      Below 1 Ω
      E12-8 - z36-1
      Always
      Below 1 Ω
      E12-8 - z37-2
      Always
      Below 1 Ω
      E12-7 - z37-1
      Always
      Below 1 Ω

      NOTICE:
      As the spiral cable may break, do not rotate the spiral cable more than the specified amount.

← REMOVAL (from Jan 2012)INSTALLATION (Sep 2011 – Dec 2011) →