2011-2013 Land Cruiser · Service Manual Vehicle Interior

B1419/19 Rear Room Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

The rear room temperature sensor LH*1 or RH*2 (for driver side) is installed in the rear quarter trim board LH*1 or RH*2 to detect the rear room temperature and control the heater and air conditioner "auto" mode. The resistance of the rear room temperature sensor LH*1 or RH*2 changes in accordance with the rear room temperature for the LH*1 or RH*2 seat. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the rear room temperature sensor LH*1 or RH*2 and reads voltage changes as changes in the resistance of the rear room temperature sensor LH*1 or RH*2.
DTC Code
DTC Detection Condition
Trouble Area
B1419/19
An open or short in the rear room temperature sensor LH*1 or RH*2 circuit.
  1. Rear room temperature sensor LH*1
  2. Rear room temperature sensor RH*2
  3. Harness or connector between rear room temperature sensor LH and air conditioning amplifier assembly*1
  4. Harness or connector between rear room temperature sensor RH and air conditioning amplifier assembly*2
  5. Air conditioning amplifier assembly

HINT:
*1: for LHD
*2: for RHD


WIRING DIAGRAM

E156584E40
E156584E41

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (AIR CONDITIONER)
  1. Use the Data List to check if the rear room temperature sensor LH*1 or RH*2 is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temp Sensor (Rear)
    Rear room temperature sensor for LH*1 or RH*2 /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual rear room temperature for LH*1 or RH*2 displayed
    Open in the circuit: -6.5°C (20.3°F).
    Short in the circuit: 57.25°C (135.05°F).

    HINT:
    *1: for LHD
    *2: for RHD

    OK:
    The display is as specified in the normal condition.



NG
Go to step 2
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

2. INSPECT REAR ROOM TEMPERATURE SENSOR
E160595E03
  1. for LHD

    1. Remove the rear room temperature sensor LH (Click here).

  1. for RHD

    1. Remove the rear room temperature sensor RH (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (+) - 2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    Result 
    Result
    Proceed to
    OK
    A
    NG (for LHD)
    B
    NG (for RHD)
    C



B
REPLACE REAR ROOM TEMPERATURE SENSOR LH (Click here)

C
REPLACE REAR ROOM TEMPERATURE SENSOR RH (Click here)
A


3. CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E160312E09
  1. for LHD

    1. Disconnect the z55 sensor connector.

    2. Disconnect the E35 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      z55-1 (+) - E35-18 (TR)
      Always
      Below 1 Ω
      z55-2 (-) - E35-2 (SG-6)
      E35-18 (TR) - Body ground
      Always
      10 kΩ or higher
      E35-2 (SG-6) - Body ground

  1. E160312E10
    for RHD
    1. Disconnect the z56 sensor connector.

    2. Disconnect the E35 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      z56-2 (-) - E35-2 (SG-6)
      Always
      Below 1 Ω
      z56-1 (+) - E35-19 (TR7)
      E35-2 (SG-6) - Body ground
      Always
      10 kΩ or higher
      E35-19 (TR7) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)