2011-2013 Land Cruiser · Service Manual Drivetrain

INSPECTION

Inspection · Vehicles built from Sep 2011


INSPECT SHIFT SOLENOID VALVE SR

C158386E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (SR) - Solenoid Body (SR)
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve SR connector
    2. Battery negative (-) → Shift solenoid valve SR body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLU

C162477E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SLU - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL2

C151311E13
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SL2 - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 1
    2. Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLT

C162477E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SLT - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL1

C151311E15
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SL1 - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 1
    2. Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE S1

C159062E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S1) - Solenoid Body (S1)
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S1 connector
    2. Battery negative (-) → Shift solenoid valve S1 body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.


INSPECT SHIFT SOLENOID VALVE S2

C158386E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S2) - Solenoid Body (S2)
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S2 connector
    2. Battery negative (-) → Shift solenoid valve S2 body
    Valve moves and makes an operating noise

    If the result is not as specified, replace the solenoid valve.

← DISASSEMBLY (from Sep 2011)REASSEMBLY (from Sep 2011) →