INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT HEATED OXYGEN SENSOR |
Measure the heater resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (HT1B) - 2 (+B)
(for Bank 1)
20°C (68°F)
11 to 16 Ω
1 (HT2B) - 2 (+B)
(for Bank 2)
If the result is not as specified, replace the sensor.Text in Illustration *A
for Bank 1
*B
for Bank 2
*a
Component without harness connected
(Heated Oxygen Sensor)