INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT HEADLIGHT LEVELING SWITCH |
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
1 (+B) - 2 (T)
0
0.84 to 1.56 V
1
2.12 to 2.84 V
2
3.40 to 4.12 V
3
4.68 to 5.40 V
4
6.96 to 6.68 V
5
7.24 to 7.96 V