ON-VEHICLE INSPECTION
Inspection · Vehicles built Sep 2011 – Dec 2011
| INSPECT CIRCUIT OPENING RELAY (C/OPN) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage is not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage is applied to terminals 1 and 2
Below 1 Ω
| INSPECT INTEGRATION RELAY (IG2) |
Measure the resistance of the IG2 MAIN fuse.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
IG2 MAIN fuse
Always
Below 1 Ω
Measure the resistance of the ignition relay No. 2 (IG2) circuit.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1B-8
Battery voltage is not applied to terminals 1B-6 and 1B-7
10 kΩ or higher
Battery voltage is applied to terminals 1B-6 and 1B-7
Below 1 Ω
| INSPECT INTEGRATION RELAY (EFI) |
Measure the resistance of the EFI MAIN fuse.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
EFI MAIN fuse
Always
Below 1 Ω
Measure the resistance of the EFI relay circuit.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1B-4
Battery voltage is not applied to terminals 1B-2 and 1B-3
10 kΩ or higher
Battery voltage is applied to terminals 1B-2 and 1B-3
Below 1 Ω
| INSPECT EFI NO. 2 RELAY (EFI NO. 2) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage is not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage is applied to terminals 1 and 2
Below 1 Ω
| INSPECT INTEGRATION RELAY (A/F) |
Measure the resistance of the A/F fuse.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A/F fuse
Always
Below 1 Ω
Measure the resistance of the A/F sensor heater relay circuit.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1A-4
Battery voltage is not applied to terminals 1A-2 and 1A-3
10 kΩ or higher
Battery voltage is applied to terminals 1A-2 and 1A-3
Below 1 Ω
| INSPECT MAIN BODY ECU (IG1 NO. 1) |
Measure the resistance according to the value(s) in the table below.


- Standard Resistance:
Tester Condition
Condition
Specified Condition
2A-1 - 2B-17
Battery voltage is not applied to terminals 2B-5 and 2D-43
10 kΩ or higher
Battery voltage is applied to terminals 2B-5 and 2D-43
Below 1 Ω
| INSPECT STARTER RELAY (ST) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage applied to terminals 1 and 2
Below 1 Ω
| INSPECT STARTER CUT RELAY (ST CUT) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage applied to terminals 1 and 2
Below 1 Ω
| INSPECT MAIN BODY ECU (ACC RELAY) |


Measure the resistance of the ACC relay circuit.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
2A-1 - 2D-8
Battery voltage not applied between 2D-45 and 2D-62
10 kΩ or higher
Battery voltage applied between 2D-45 and 2D-62
Below 1 Ω