INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT COOLER CONTROL SWITCH SUB-ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
1 - 2
On
Below 1 Ω
1 - 2
Off
10 kΩ or higher
Apply battery voltage to the cooler control switch connector and check that the indicator illuminates.
- OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 3
Battery negative (-) → Terminal 4
indicator illuminates
| INSPECT NO. 1 COOLER BLOWER MOTOR SUB-ASSEMBLY |
![]() ![]() |
Apply battery voltage to the blower motor connector and check the operation of the blower motor.
- OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Motor operates smoothly
| INSPECT NO. 3 COOLER THERMISTOR |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
-10°C (14°F)
7.40 to 9.20 kΩ
1 - 2
-5°C (23°F)
5.65 to 7.00 kΩ
1 - 2
0°C (32°F)
4.35 to 5.40 kΩ
1 - 2
5°C (41°F)
3.40 to 4.20 kΩ
1 - 2
10°C (50°F)
2.68 to 3.30 kΩ
1 - 2
15°C (59°F)
2.10 to 2.60 kΩ
1 - 2
20°C (68°F)
1.66 to 2.10 kΩ
1 - 2
25°C (77°F)
1.32 to 1.66 kΩ
1 - 2
30°C (86°F)
1.05 to 1.35 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
- If the result is not as specified, replace the cooler thermistor.