CONSTRUCTION
A double outlet pump, in which the washer pumps for front and rear washer spray operations are integrated, is used to achieve weight reduction.
| *1 | Housing | *2 | Impeller |
| *3 | Valve Sub-assembly | *4 | Diaphragm |
OPERATION
Windshield Washer Motor and Pump Assembly
When washer fluid is sprayed, the motor rotates in the normal or reverse direction according to the upward or downward sweep operation. As a result, the impeller is rotated so that washer fluid is pressure-fed.
Due to the differential pressure between the discharge side and non-discharge side generated by the impeller rotation, the pressure on the discharge side becomes higher than the non-discharge side. As a result, the spraying passage on the opposite side is blocked by the diaphragm and washer fluid only sprays on the discharge side.