CONSTRUCTION
A wastegate valve is used for the turbocharger sub-assembly, so that when the vehicle is being driven at low load (supercharging not necessary), the back pressure decreases, reducing pumping loss during the exhaust stroke according to the wastegate valve opening. In addition, by opening the wastegate valve even when the engine is started, high temperature exhaust gas is supplied to the catalyst, shortening warm-up time.
An electric wastegate actuator is used, allowing for fine boost pressure control. The electric wastegate actuator opens and closes the wastegate valve according to signals received from the ECM.
A small turbine housing scroll is achieved, while the wastegate port diameter, bypass passage and wastegate valve opening angle are optimized, so that exhaust gas makes direct contact with the catalyst, in order to accelerate catalyst warm-up and reduce emissions.
An electric air by-pass valve is used in the air tube sub-assembly to prevent the surge phenomenon* from occurring. When the throttle valve closes with the accelerator pedal released, the pressure between the turbocharger sub-assembly and throttle valve increases. This pressure is diverted upstream to the turbocharger sub-assembly when the air by-pass valve opens.
* Surge phenomenon: This phenomenon is when the intake airflow reverses. As a result, an abnormal noise is easily generated during deceleration.
| *1 | Turbocharger Sub-assembly | *2 | Wastegate Valve Actuator |
| *3 | Turbine Wheel | *4 | Compressor Wheel |
| *5 | Wastegate Valve | - | - |
| *a | Exhaust Gas | *b | Intake Air |
| *c | Bypass Gas | *d | View from A |
OPERATION
Wastegate Valve
When the engine is stopped, the wastegate valve is open.
The electric wastegate actuator operates according to signals from the ECM and opens the wastegate valve after a specified amount of time elapses after starting the engine with a light engine load.
When the engine is under high load or accelerating, fine control is performed to open and close the wastegate valve.
| *1 | Compressor Wheel | *2 | Turbine Wheel |
| *3 | Wastegate Valve | *4 | Wastegate Valve Actuator |
| *5 | ECM | - | - |
|
Exhaust Gas |
|
Intake Air |
| *1 | Compressor Wheel | *2 | Turbine Wheel |
| *3 | Wastegate Valve | *4 | Wastegate Valve Actuator |
| *5 | ECM | - | - |
|
Exhaust Gas |
|
Intake Air |
Air By-pass Valve
The air by-pass valve assembly opens according to signals from the ECM to divert the pressure between the turbocharger sub-assembly and throttle valve, which is increased when the throttle valve is closed, upstream of the turbocharger sub-assembly.
| *1 | ECM | *2 | Air By-pass Valve Assembly |
| *3 | Compressor Wheel | *4 | Turbine Wheel |
| *5 | Coil | *6 | Shaft |
| *7 | Valve | - | - |
| *a | To Throttle Body with Motor Assembly | *b | Air By-pass Valve Assembly Cross Section |
|
Exhaust Gas |
|
Intake Air |
| *1 | ECM | *2 | Air By-pass Valve Assembly |
| *3 | Compressor Wheel | *4 | Turbine Wheel |
| *5 | Coil | *6 | Shaft |
| *7 | Valve | - | - |
| *a | To Throttle Body with Motor Assembly | *b | Air Bypass Valve Cross Section |
|
Exhaust Gas |
|
Intake Air |