OUTLINE
A tandem solenoid type starter assembly is used. This starter uses a structure in which the flow of current is independently supplied to the motor current solenoid and the solenoid used to push out the pinion gear. Due to this, it is possible to restart the engine when the engine has been stopped but is still moving due to inertia, thereby reducing the amount of time to restart the engine during idling stop control.*
*: Models with stop and start system
A planetary type starter assembly is used.*
*: Models without stop and start system
A starter control (cranking hold function) is used.
SPECIFICATION
|
*1: Length from the mounted area to the rear end of the starter *2: Viewed from pinion side |
||
| Model | Models with Stop and Start System | Models without Stop and Start System |
| Rating Output | 1.6 kW | 1.7 kW |
| Rating Voltage | 12 V | 12 V |
| Length*1 | 169.0 mm (6.65 in.) | 165.8 mm (6.53 in.) |
| Weight | 3700 g (8.2 lb) | 3450 g (7.6 lb) |
| Rotational Direction*2 | Clockwise | Clockwise |