CONSTRUCTION
No. 1 Cooler Evaporator Sub-assembly
Cross-turn Type Evaporator
An cross-turn evaporator is used that closes the refrigerant passage in the evaporator within the intermediate tank. This reduces pressure loss in the evaporator, keeps the surface temperature of the evaporator distributed evenly, and ensures a high level of cooling performance.
| *a | Separator | *b | Tank Header |
| *c | Intermediate Tank (Sub Tank) | *d | Plate |
| *e | Intermediate Tank (Tank Cover) | *f | Micropore Tube |
| *g | Cooling Fin | *h | This illustration is an example only. |
Evaporator Sub-assembly (Rear) (Models with Rear Cooling Unit or Rear Air Conditioning Unit)
Cross-turn Type Evaporator
An cross-turn evaporator is used that closes the refrigerant passage in the evaporator within the intermediate tank. This reduces pressure loss in the evaporator, keeps the surface temperature of the evaporator distributed evenly, and ensures a high level of cooling performance.
| *a | Intermediate Tank | *b | Cooling Fin |
| *c | Micropore Tube | - | - |
OPERATING
Operation of cross-turn type evaporator
Refrigerant flowing in from the condenser assembly is split into 2 systems and flows into the evaporator. Refrigerant dropped from the upper tank turns in a crossing direction within the intermediate tank, rises upward, and then is discharged out from the evaporator.
A plate is provided in the intermediate tank. Refrigerant flowing along passage A-B passes through the outside of the plate, while refrigerant flowing along passage C-D passes through the inside of the plate, allowing refrigerant to flow in a crossing direction within the intermediate tank.
| *1 | Evaporator Sub-assembly | *2 | Upper Tank |
| *3 | Intermediate Tank | - | - |
| *a | Intermediate Tank Entry Opening | *b | Intermediate Tank Exit Opening |
| *c | This illustration is an example only. | - | - |