Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › ENTRY AND START SYSTEM
NM38G0E _58 Vehicle Interior _102330 THEFT DETERRENT / KEYLESS ENTRY _0481981 ENTRY AND START SYSTEM DE DETAILS F

THEFT DETERRENT / KEYLESS ENTRY  ENTRY AND START SYSTEM  DETAILS  CERTIFICATION ECU  


CONSTRUCTION


a.

The certification ECU includes the IGP relay and IGR relay actuation circuits, CPU and hold circuit.


b.

The hold circuit is provided to prevent the power supply to the relays from being cut off when an abnormality occurs in the IGP relay and/or IGR relay actuation circuits while driving.

HINT:

The certification ECU constantly stores the present power source mode in its memory. Therefore, if the power to the certification ECU is interrupted due to the removal of the battery, the certification ECU restores the power source after the battery is reconnected. For this reason, if the battery is removed when the power source is in a mode other than off, the power will be restored to the vehicle at the same time the power is restored to the certification ECU by reconnecting the battery. Therefore, before removing the battery, be sure to turn the power source off.