OUTLINE
A planetary type starter assembly is used.
A starter control (cranking hold function) is used.
An Inrush Current Reduction (ICR) relay, which is built into the planetary type starter assembly, is used. The ICR relay stabilizes the vehicle power source voltage during starter motor operation.*
*: Models with stop and start system
SPECIFICATION
|
*1: Length from the mounted area to the rear end of the starter *2: Viewed from pinion side |
||
| Model | Cold AreaSpecification Models | Except Cold Area Specification Models |
| Rating Output | 2.7 kW | 2.0 kW |
| Rating Voltage | 12 V | 12 V |
| Length*1 | 249.5 mm (9.82 in.) | 214.6 mm (8.45 in.) |
| Weight | 7800 g (17.2 lb) | 5250 g (11.6 lb) |
| Rotational Direction*2 | Clockwise | Clockwise |
|
*1: Length from the mounted area to the rear end of the starter *2: Viewed from pinion side |
|
| Rating Output | 1.9 kW |
| Rating Voltage | 12 V |
| Length*1 | 214.6 mm (8.45 in.) |
| Weight | 5600 g (12.3 lb) |
| Rotational Direction*2 | Clockwise |