Home › Engine / Hybrid System › F33A-FTV (EMISSION CONTROL) › CATALYST SUPPORT CONTROL SYSTEM › from 2021.07
NM38G0E _51 Engine / Hybrid System _106497 F33A-FTV EMISSION CONTROL _0489399 CATALYST SUPPORT CONTROL SYSTEM CO CONTROL F

F33A-FTV EMISSION CONTROL  CATALYST SUPPORT CONTROL SYSTEM  CONTROL  CATALYST SUPPORT CONTROL  


FUNCTION OF MAIN COMPONENTS


Component Function

*1: Models without UREA SCR system

*2: Models with UREA SCR system

ECM Controls the catalyst support control based on signals from each sensor.
Differential Pressure Sensor
·

Detects the pressure difference before and after the DPF catalyst*1 or SCR-DPF catalyst*2.

·

Compares this data with the PM accumulation amount calculated by the ECM. If there is a large deviation in the comparison result, the ECM corrects the PM accumulation amount.


Exhaust Gas Temperature Sensor Detects the exhaust gas temperature.
No. 2 Exhaust Gas Temperature Sensor
No. 3 Exhaust Gas Temperature Sensor
Air Fuel Ratio Sensor*1 Detects the oxygen concentration in exhaust gas.
No. 1 Nitrogen Oxides Sensor*2
Exhaust Fuel Addition Injector Assembly Injects fuel inside the exhaust manifold converter sub-assembly based on signals from the ECM.
Front Exhaust Pipe Sub-assembly DPF Catalyst*1 Collects PM from within the exhaust gas.
SCR-DPF Catalyst*2
DPR Switch Assembly Manual PM regeneration can be performed when PM of the specified value or higher is accumulated in the DPF catalyst*1 or SCR-DPF catalyst*2.
Combination Meter Assembly MIL Illuminates when the DPF catalyst*1 or SCR-DPF catalyst*2 cannot be regenerated.
Multi-information Display
·

The amount of accumulated PM in the DPF catalyst*1 or SCR-DPF catalyst*2 can be checked from the PM accumulation monitor.

·

Displays a message in accordance with the amount of accumulated PM.




SYSTEM CONTROL


a.

In order to regenerate the DPF catalyst*1 or SCR-DPF catalyst*2, the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 is increased to combust the accumulated PM in the DPF catalyst*1 or SCR-DPF catalyst*2, expelling it as CO2 and H2O.


b.

If the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 does not increase and the PM keeps accumulating in the DPF catalyst*1 or SCR-DPF catalyst*2, a message and the amount of accumulated PM (in 10 levels) are simultaneously displayed on the multi-information display to notify the driver.


c.

The ECM monitors the engine condition and calculates the total amount of accumulated PM. In addition, the ECM calculates the amount of combusted PM according to the engine speed, fuel injection volume and the injection volume of the exhaust fuel addition injector assembly. The amount of accumulated PM in the DPF catalyst*1 or SCR-DPF catalyst*2 is calculated based on the calculated total amount of accumulated PM and the amount of combusted PM. The ECM urges the driver to perform PM automatic or manual regeneration according to the level of accumulated PM.


d.

When automatic or manual regeneration is performed, the injection of the exhaust fuel addition injector assembly and the engine combustion condition are controlled, increasing the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2. As a result, the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 becomes approximately 600°C to 700°C and PM is combusted.


e.

When the vehicle is continuously driven with a high exhaust temperature such as at high speeds, the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 is sufficiently increased and PM is spontaneously combusted. At this time, no special control such as exhaust fuel addition injector assembly control, etc. is performed.


f.

When the vehicle is continuously driven while the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 is not high enough for PM combustion such as when driving for a short distance or driving for a short time, catalyst performance is decreased. As a result, PM is accumulated in the DPF catalyst*1 or SCR-DPF catalyst*2. When the amount of accumulated PM exceeds the threshold (for automatic regeneration), the ECM performs automatic regeneration until the amount of PM reaches zero.

*1: Models without UREA SCR system

*2: Models with UREA SCR system



g.

If the vehicle continues to be driven for a short distance even after automatic regeneration is performed, more PM is accumulated. When the amount of accumulated PM exceeds the threshold (for manual regeneration), a message and the amount of accumulated PM are simultaneously displayed on the multi-information display to urge the driver to perform manual regeneration.


h.

Automatic Regeneration

i.

When automatic regeneration is being performed, the ECM controls the fuel injection of the exhaust fuel addition injector assembly and the engine combustion condition, increasing the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 to combust the PM. Idle up is performed while the vehicle is stopped.

HINT:

The end of automatic regeneration is calculated by the ECM according to the amount of accumulated PM.


*1: Models without UREA SCR system

*2: Models with UREA SCR system




i.

Manual Regeneration

i.

The following methods are used to perform manual regeneration. For details of manual regeneration operation, refer to the Repair Manual.

1.

DPR Switch Operation Method

Stop the vehicle and press the DPR switch to perform manual regeneration.

HINT:

Operating the accelerator pedal (models with an automatic transmission) or operating the clutch pedal and accelerator pedal (models with a manual transmission) while regeneration is being performed temporarily stops regeneration.



2.

Global TechStream (GTS) Operation Method

Stop the vehicle and operate the GTS to perform manual regeneration.




ii.

When manual regeneration is being performed, the ECM controls the fuel injection of the exhaust fuel addition injector assembly and the engine combustion condition and performs idle up, increasing the temperature of the DPF catalyst*1 or SCR-DPF catalyst*2 to combust the PM.

HINT:

The end of manual regeneration is calculated by the ECM according to the amount of accumulated PM.


*1: Models without UREA SCR system

*2: Models with UREA SCR system




j.

Fail-safe

i.

If manual regeneration is performed when the amount of accumulated PM is beyond the threshold, the DPF catalyst*1 or SCR-DPF catalyst*2 may get damaged. Therefore, when the amount of accumulated PM exceeds the threshold (for the fail-safe function), the injection volume is controlled to a minimum level to cancel regeneration control. As a result, manual regeneration cannot be performed properly. At the same time, the MIL illuminates and a message is displayed on the multi-information display to notify the driver of a malfunction.

*1: Models without UREA SCR system

*2: Models with UREA SCR system


Relationship between MIL, Message on Multi-information Display and Regeneration Control (Conceptual Diagram)
W142585E01
2.635,4.177 2.865,4.177 2.865,4.177 2.938,3.563 true 1.948,1.094 2.094,1.094 2.094,1.094 2.552,1.438 true 2.031,0.646 2.177,0.646 2.177,0.646 2.552,1.094 true 0.531,0.052 2.219,0.344 1.688,0.292 10 false : Automatic regeneration 3.688,0.052 5.375,0.344 1.688,0.292 10 false : Manual regeneration 0.052,1.677 0.927,2.573 0.875,0.896 10 false PM Accumulation 0.521,0.583 2.021,0.99 1.5,0.406 10 false Threshold (for Fail-safe) 0.552,1.021 1.896,1.552 1.344,0.531 10 false Threshold (for Manual Regeneration) 0.99,2.729 2.563,3.333 1.573,0.604 10 false Threshold (for Automatic Regeneration) 2.625,0.781 4.458,1.115 1.833,0.333 10 false Fail-safe Range 2.594,1.104 4.427,1.438 1.833,0.333 10 false Manual Regeneration Range 1.104,4.094 2.698,4.406 1.594,0.313 10 false Normal Operation Range 6.646,2.479 6.802,2.677 0.156,0.198 10 false A 6.677,1.521 6.833,1.719 0.156,0.198 10 false B 6.646,1.177 6.802,1.375 0.156,0.198 10 false C 6.646,0.865 6.802,1.063 0.156,0.198 10 false D 3.99,3.698 5.427,4.229 1.438,0.531 10 false Traveled Distance 2.573,1.438 4.823,1.688 2.25,0.25 10 false Automatic Regeneration Range

Text in Illustration MIL Message on Multi-information Display
A - -
DPF Regeneration in Progress
B - DPF Full See Owner's Manual
C - DPF Full Manual Regeneration Required See Owner's Manual
D Illuminate DPF Full Visit Your Dealer

W149209C01
2.635,1.76 3.375,1.146 3.375,1.146 3.531,1.146 true 3.771,1.708 4.51,1.708 true 2.167,0.75 2.479,0.906 0.313,0.156 10 false *1 0.49,2.229 0.979,2.427 0.49,0.198 10 false *2 3.583,1.073 4.063,1.281 0.479,0.208 10 false *3 0.292,0.052 0.844,0.292 0.552,0.24 12 false *A: 3.594,0.083 4.146,0.323 0.552,0.24 12 false *B: 4.844,0.781 5.156,0.938 0.313,0.156 10 false *1 6.5,2.219 6.99,2.417 0.49,0.198 10 false *2 3.604,1.625 4.083,1.833 0.479,0.208 10 false *3
*A LHD Models *B RHD Models
*1 MIL *2 DPR Switch Assembly
*3 Multi-information Display - -