CONSTRUCTION
A compact and lightweight vane pump, which uses die-cast aluminum as the material for its housing, is used.
A belt drive type vane pump is used on models with the 1GR-FE or V35A-FTS engine.
A gear drive type vane pump is used on models with the F33A-FTV engine.
A VFC solenoid valve is provided to control the discharge flow rate.*
*: Models with VFC power steering
| *1 | Shaft with Pulley | *2 | Vane Pump Housing |
| *1 | Shaft with Pulley | *2 | VFC Solenoid Valve |
| *3 | Vane Pump Housing | - | - |
| *1 | Vane Pump Housing | *2 | VFC Solenoid Valve |