Home › Engine / Hybrid System › F33A-FTV (EMISSION CONTROL) › UREA SELECTIVE CATALYTIC REDUCTION SYSTEM › from 2021.07
NM38G0E _51 Engine / Hybrid System _106497 F33A-FTV EMISSION CONTROL _0489398 UREA SELECTIVE CATALYTIC REDUCTION SYSTEM DE DETAILS F

F33A-FTV EMISSION CONTROL  UREA SELECTIVE CATALYTIC REDUCTION SYSTEM  DETAILS  UREA PUMP  


CONSTRUCTION


a.

A urea pump integrated with the urea pump control ECU is used. It is placed on the lower urea tank sub-assembly.

W148714C01
5.094,1.302 4.583,0.729 4.583,0.729 4.427,0.729 true 4.51,4.219 4.99,4.219 true 3.24,4.031 3.031,4.031 3.031,4.031 2.198,2.677 true 1.542,2.042 0.76,0.813 0.76,0.813 0.563,0.813 true 4.792,1.76 4.573,1.5 4.573,1.5 4.417,1.5 true 5.969,2.865 5.792,2.865 5.792,2.865 5.427,3.313 true 5.083,2.26 4.625,2.094 4.625,2.094 4.469,2.094 true 0.396,0.76 0.708,0.917 0.313,0.156 10 false *1 3.281,3.958 3.594,4.115 0.313,0.156 10 false *2 4.25,0.667 4.563,0.823 0.313,0.156 10 false *3 4.24,1.438 4.552,1.594 0.313,0.156 10 false *4 4.292,2.042 4.604,2.198 0.313,0.156 10 false *5 6.031,2.792 6.344,2.948 0.313,0.156 10 false *6 4.313,4.146 4.625,4.302 0.313,0.156 10 false *7
*1 Urea Solution Level Sensor *2 Urea Solution Concentration Sensor
*3 Heater *4 Filter
*5 Pump Motor *6 Pressure Sensor
*7 Urea Pump Control ECU - -



b.

The urea pump has the following functions:

Function Outline
Pump Function While performing feedback control according to the pressure sensor inside the urea pump, the pump raises the pressure to approximately 500 kPa, sending urea solution to the urea injector set.
Heating Function The heater inside the urea pump is operated to thaw the urea solution so that exhaust gas can be purified even when the ambient temperature is low and the urea solution freezes. The heater turns on and off according to the urea solution temperature sensor inside the urea pump.
Filter Function Foreign matter that enters the urea tank sub-assembly is collected by the filter inside the urea pump, preventing foreign matter from getting jammed in the urea pump and urea injector set.
Level Gauge Function The fluid level position is detected by the urea solution level sensor in the urea pump, and the remaining amount of urea solution in the urea tank sub-assembly is detected.
Concentration Detection Function The concentration of urea solution in the urea tank sub-assembly is detected by the urea solution concentration sensor in the urea pump.