1.INSPECT LEVEL WARNING SWITCH
Measure resistance
Add washer fluid to the washer jar with the level warning switch assembly installed to the washer jar.
| *a | Component without harness connected (Level Warning Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B51)Location & Routingewd_type=routing;type=c;code=B51 |
||
| B51-1 (S) - B51-2 (E) | Fluid volume is 600 to 800 cc (36.7 to 48.8 cu. in.) or more* | 10 kΩ or higher |
| B51-1 (S) - B51-2 (E) | Fluid volume is 600 to 800 cc (36.7 to 48.8 cu. in.) or less* | Below 1 Ω |
Perform checks by reducing the amount of washer fluid.
*: The level warning switch assembly activates when the washer fluid is 600 to 800 cc or less according to the vehicle condition (vehicle stability etc.)