Home › Drivetrain › AJA0F (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY
RM38G0E _52 Drivetrain _100435 AJA0F AUTOMATIC TRANSMISSION / TRANSAXLE _0467303 VALVE BODY ASSEMBLY G

AJA0F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35210A 1.INSPECT SOLENOID (SL1) VALVE

a.
C197715C49
1.792,0.948 2.24,0.365 true 1.438,0.938 0.979,0.354 true 1.813,2.917 2.26,2.323 true 1.438,2.927 0.979,2.333 true 0.052,0.01 0.365,0.208 0.313,0.198 10 false *a 2.26,0.25 2.427,0.448 0.167,0.198 10 false 1 0.854,0.26 1.021,0.458 0.167,0.198 10 false 2 2.292,2.208 2.458,2.406 0.167,0.198 10 false 1 0.844,2.24 1.01,2.438 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)
*a Component without harness connected
(Solenoid (SL1) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Connect a positive (+) lead with a 21 W bulb from the battery to terminal 1 and a negative (-) lead to terminal 2 of the solenoid (SL1) valve connector and check the operation of the valve.

OK:

The valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SL1) valve.


Hide 35210C 2.INSPECT SOLENOID (SL2) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35210B 3.INSPECT SOLENOID (SL3) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35210D 4.INSPECT SOLENOID (SL4) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35210E 5.INSPECT SOLENOID (SL5) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35210E 6.INSPECT SOLENOID (SL6) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35290C 7.INSPECT SOLENOID (SLT) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35280A 8.INSPECT SOLENOID (SLU) VALVE

HINT:

Use the same procedure as for the solenoid (SL1) valve.


Hide 35240K 9.INSPECT SOLENOID (SC1) VALVE

a.
C375005C01
0.063,0.042 0.375,0.198 0.313,0.156 10 false *a
*a Component without harness connected
(Solenoid (SC1) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid (SC1) valve connector terminal - Solenoid (SC1) valve body 20°C (68°F) 11 to 15 Ω



b.

Connect a positive (+) lead from the battery to the terminal of the solenoid (SC1) valve connector, and a negative (-) lead to the solenoid (SC1) valve body, and check the operation of the valve.

OK:

The valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SC1) valve.


Hide 35240R 10.INSPECT SOLENOID (SR) VALVE

HINT:

Use the same procedure as for the solenoid (SC1) valve.


Hide 35240S 11.INSPECT SOLENOID (SL) VALVE

HINT:

Use the same procedure as for the solenoid (SC1) valve.