Home › Drivetrain › AJA0F (AUTOMATIC TRANSMISSION / TRANSAXLE) › PARK / NEUTRAL POSITION SWITCH
RM38G0E _52 Drivetrain _100435 AJA0F AUTOMATIC TRANSMISSION / TRANSAXLE _0467302 PARK / NEUTRAL POSITION SWITCH G

AJA0F AUTOMATIC TRANSMISSION / TRANSAXLE  PARK / NEUTRAL POSITION SWITCH  INSPECTION  


PROCEDURE

Hide 84540 1.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

a.
C193931C71
0.115,1.094 0.573,1.365 0.458,0.271 2.167,0.25 1.833,0.25 1.833,0.25 1.625,0.938 true 2.583,0.5 2.333,0.5 2.333,0.5 2.042,1 true 2.167,2 1.917,2 1.917,2 1.792,1.479 true 0.833,1.833 1.083,1.833 1.083,1.833 1.24,1.469 true 2.844,2 2.594,2 2.594,2 2.167,1.458 true 0.76,0.625 1.01,0.625 1.01,0.625 1.146,0.938 true 2.896,1.74 2.646,1.74 2.646,1.74 2.323,1.49 true 2.219,0.156 2.583,0.396 0.365,0.24 10 false RB 2.635,0.406 2.958,0.604 0.323,0.198 10 false RL 0.635,1.75 1.104,1.938 0.469,0.188 10 false NL 2.219,1.927 2.74,2.094 0.521,0.167 10 false DL 0.104,0.073 0.281,0.271 0.177,0.198 10 false *a 2.865,1.885 3.385,2.052 0.521,0.167 10 false PL 0.24,1.167 0.698,1.365 0.458,0.198 10 false C34 0.552,0.51 0.917,0.75 0.365,0.24 10 false B 2.927,1.625 3.375,1.823 0.448,0.198 10 false L
*a Component without harness connected
(Park/Neutral Position Switch Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(C34)Location & Routing

Click Connector(C34)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>Park/Neutral Position Switch Assembly

C34-4 (B) - C34-5 (L) Shift lever in P or N Below 1 Ω
Shift lever not in P or N 10 kΩ or higher
C34-2 (RB) - C34-6 (PL) Shift lever in P Below 1 Ω
Shift lever not in P 10 kΩ or higher
C34-2 (RB) - C34-1 (RL) Shift lever in R Below 1 Ω
Shift lever not in R 10 kΩ or higher
C34-2 (RB) - C34-9 (NL) Shift lever in N Below 1 Ω
Shift lever not in N 10 kΩ or higher
C34-2 (RB) - C34-7 (DL) Shift lever in D, M, "+" or "-" Below 1 Ω
Shift lever not in D, M, "+" or "-" 10 kΩ or higher


If the resistance value is not as specified, replace the park/neutral position switch assembly.