89467B 1.INSPECT AIR FUEL RATIO SENSOR
| *A | for Bank 1 |
| *B | for Bank 2 |
| *a | Component without harness connected (Air Fuel Ratio Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C87)Location & Routingewd_type=routing;type=c;code=C87 |
||
| C87-1 (HA1A) - C87-2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| C87-1 (HA1A) - C87-4 (A1A-) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C88)Location & Routingewd_type=routing;type=c;code=C88 |
||
| C88-1 (HA2A) - C88-2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| C88-1 (HA2A) - C88-4 (A2A-) | Always | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor.