Home › Engine / Hybrid System › 1GR-FE (ENGINE CONTROL) › AIR FUEL RATIO SENSOR
RM38G0E _51 Engine / Hybrid System _100527 1GR-FE ENGINE CONTROL _0467389 AIR FUEL RATIO SENSOR G

1GR-FE ENGINE CONTROL  AIR FUEL RATIO SENSOR  INSPECTION  


PROCEDURE

Hide 89467B 1.INSPECT AIR FUEL RATIO SENSOR

A159233C05
1.51,0.969 1.896,1.177 0.385,0.208 1.51,1.26 1.896,1.469 0.385,0.208 1.479,1.969 1.073,1.406 1.073,1.406 0.917,1.406 true 1.979,2 2.302,1.292 2.302,1.292 2.458,1.292 true 0.844,2 1,2 1,2 1.469,2.323 true 2.563,1.198 3.198,1.448 0.635,0.25 10 false HA1A *A 0.615,1.292 0.906,1.49 0.292,0.198 10 false +B 0.281,1.938 0.802,2.125 0.521,0.188 10 false A1A- *A 2.563,1.417 3.198,1.677 0.635,0.26 10 false HA2A *B 0.292,2.146 0.813,2.333 0.521,0.188 10 false A2A- *B 0.125,0.104 0.438,0.26 0.313,0.156 10 false *a 1.563,1.292 1.906,1.49 0.344,0.198 10 false C88 1.563,1 1.875,1.219 0.313,0.219 10 false C87 1.927,0.979 2.198,1.167 0.271,0.188 10 false *A 1.948,1.271 2.219,1.458 0.271,0.188 10 false *B
*A for Bank 1
*B for Bank 2
*a Component without harness connected
(Air Fuel Ratio Sensor)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition

Click Location & Routing(C87)Location & Routing

Click Connector(C87)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>Air Fuel Ratio Sensor (Bank 1 Sensor 1)

C87-1 (HA1A) - C87-2 (+B) 20°C (68°F) 1.6 to 3.2 Ω
C87-1 (HA1A) - C87-4 (A1A-) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition

Click Location & Routing(C88)Location & Routing

Click Connector(C88)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>Air Fuel Ratio Sensor (Bank 2 Sensor 1)

C88-1 (HA2A) - C88-2 (+B) 20°C (68°F) 1.6 to 3.2 Ω
C88-1 (HA2A) - C88-4 (A2A-) Always 10 kΩ or higher


If the result is not as specified, replace the air fuel ratio sensor.