Home › Engine / Hybrid System › 1GR-FE (ENGINE CONTROL) › RELAY
RM38G0E _51 Engine / Hybrid System _100527 1GR-FE ENGINE CONTROL _0467392 RELAY G

1GR-FE ENGINE CONTROL  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 89561F 1.INSPECT NO. 1 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 1)

a.
A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 1 electronic fuel injection main relay (EFI MAIN NO. 1).


Hide 85917D 2.INSPECT AIR FUEL RATIO SENSOR HEATER RELAY (A/F)

A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the air fuel ratio sensor heater relay (A/F).


Hide 85935 3.INSPECT FUEL PUMP RELAY (FUEL PMP)

A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the fuel pump relay (FUEL PMP).


Hide 89589B 4.INSPECT AI VALVE RELAY (AI VLV) (w/ Secondary Air Injection System)

a.
A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the ai valve relay (AI VLV).


Hide 28371L 5.INSPECT IGP RELAY (IGP NO. 1)

a.
A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the IGP relay (IGP NO. 1).


Hide 28371M 6.INSPECT NO.2 IGP RELAY (IGP NO. 2)

A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 2 IGP relay (IGP NO. 2).


Hide 28371N 7.INSPECT NO.3 IGR RELAY (IGR NO. 3)

A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 3 IGR relay (IGR NO. 3).


Hide 28300 8.INSPECT STARTER RELAY ASSEMBLY (ST NO. 1)

a.
A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the starter relay assembly (ST NO. 1).


Hide 17616A 9.INSPECT AIR PUMP RELAY (AIR PMP HTR)

a.
A188757E05
2.708,0.573 2.833,0.208 2.833,0.208 3.052,0.208 true 2.135,0.563 2,0.208 2,0.208 1.771,0.208 true 2.646,1.115 3.063,1.115 true 2.646,1.604 3.063,1.604 true 1.646,0.125 1.802,0.323 0.156,0.198 10 false 1 3.115,0.135 3.271,0.333 0.156,0.198 10 false 2 3.125,1.031 3.281,1.229 0.156,0.198 10 false 5 3.115,1.51 3.271,1.708 0.156,0.198 10 false 3 0.313,1.25 0.469,1.448 0.156,0.198 10 false 1 0.313,0.771 0.469,0.969 0.156,0.198 10 false 3 1.323,0.771 1.479,0.969 0.156,0.198 10 false 5 1.323,1.271 1.479,1.469 0.156,0.198 10 false 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the air pump relay (AIR PMP HTR).