LOAD OPERATION OUTPUT
Load is turned on or off according to the operation signals and switch signals from each ECU.
| Components | Semiconductor Power Integration ECU | Power Distribution Box Assembly (Instrument Panel Junction Block Assembly) |
|---|---|---|
|
*1: for LED Headlight *2: w/ Fog Light *3: w/ Mirror Heater System *4: w/ Rear Fog Light |
||
| Smart LDM*1 | ○ | - |
| Fog Light Assembly*2 | ○ | - |
| Washer Level Delegated Input | ○ | - |
| Rear Window Defogger / Mirror Heater*3 | - | ○ |
| Taillight | - | ○ |
| Rear Fog Light*4 | - | ○ |
| Panel Illumination | - | ○ |
| Passenger Seat Buckle Switch Delegated Input | - | ○ |
| Occupant Detection Sensor Delegated Input | - | ○ |
| Rear Seat RH Buckle Switch Delegated Input | - | ○ |
SEMICONDUCTOR FUSE FUNCTION
When a malfunction current occurs during load operation, the current is shut off before the electrical lines emit smoke, and then load is turned off. After the current is shut off, the off condition is maintained until the operation signals or switch signals turn off.