SPECIFICATIONS METER / GAUGE / DISPLAY SERVICE DATA
TRIP SWITCH
Connector Condition
Tester Connection
Switch Condition
Specified Condition
Component without harness connected
I80-5 (+) - I80-4 (E)
ODO/TRIP switch pressed
Below 1 Ω
ODO/TRIP switch not pressed