88625U 1.INSPECT COOLER THERMISTOR (DUCT SENSOR) (for LH Side)
| *a | Component without harness connected (Cooler Thermistor (Duct Sensor)) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
| *e | Allowable Range |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(U1)Location & Routingewd_type=routing;type=c;code=U1 Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LHewd_type=component;type=c;code=U1;pinno=1,2 |
||
| U1-1 - U1-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| U1-1 - U1-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| U1-1 - U1-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| U1-1 - U1-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| U1-1 - U1-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| U1-1 - U1-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| U1-1 - U1-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| U1-1 - U1-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| U1-1 - U1-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| U1-1 - U1-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| U1-1 - U1-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
Perform the inspection without removing the cooler thermistor (duct sensor) from the quarter trim panel assembly.
Do not connect the connector without the cooler thermistor (duct sensor) installed to the quarter trim panel assembly to prevent the cooler thermistor (duct sensor) terminal from being disconnected.
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
If the result is not as specified, replace the cooler thermistor (duct sensor).
88625U 2.INSPECT COOLER THERMISTOR (DUCT SENSOR) (for RH Side)
| *a | Component without harness connected (Cooler Thermistor (Duct Sensor)) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
| *e | Allowable Range |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(R1)Location & Routingewd_type=routing;type=c;code=R1 Click Connector(R1)Body>Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear RHewd_type=component;type=c;code=R1;pinno=1,2 |
||
| R1-1 - R1-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| R1-1 - R1-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| R1-1 - R1-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| R1-1 - R1-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| R1-1 - R1-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| R1-1 - R1-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| R1-1 - R1-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| R1-1 - R1-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| R1-1 - R1-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| R1-1 - R1-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| R1-1 - R1-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
Perform the inspection without removing the cooler thermistor (duct sensor) from the quarter trim panel assembly.
Do not connect the connector without the cooler thermistor (duct sensor) installed to the quarter trim panel assembly to prevent the cooler thermistor (duct sensor) terminal from being disconnected.
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
If the result is not as specified, replace the cooler thermistor (duct sensor).