The cooler thermistor (room temperature sensor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler thermistor (room temperature sensor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the cooler thermistor (room temperature sensor) and reads voltage changes due to changes in the resistance of the cooler thermistor (room temperature sensor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B141A11 | Room Temperature Sensor Circuit Short to Ground | Diagnosis Condition: Ignition switch ON Malfunction Status: Short in room temperature sensor circuit Detection Time: Continuously for 4 seconds or more |
·
Cooler thermistor (room temperature sensor)
·
Harness or connector
·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
Pre-procedure1
Disconnect the I37 cooler thermistor (room temperature sensor) connector.
| *1 | Cooler Thermistor (Room Temperature Sensor) |
| *2 | Air Conditioning Amplifier Assembly |
Procedure1
According to the display on the GTS, read the Data List.
| Tester Display |
|---|
| Room Temperature Sensor |
| GTS Display | Specified Condition |
|---|---|
| Room Temperature Sensor | -327.68°C (-557.82°F) |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR (for Front Side)>REMOVAL
NG
Pre-procedure1
Disconnect the I32 air conditioning amplifier assembly connector.
Disconnect the I37 cooler thermistor (room temperature sensor) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I32,I37)Location & Routingewd_type=routing;type=c,c;code=I32,I37 |
||
| I32-5 (TR) or I37-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| I32-3 (SG-1) or I37-2 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG