Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM38G0E _58 Vehicle Interior _100766 HEATING / AIR CONDITIONING _0467925 AIR CONDITIONING SYSTEM J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Front Window Fogging  


DESCRIPTION

If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.

Symptom Factor
Front glass fogs up

(Does not cool)


·

Cooler compressor assembly malfunction

·

Quantity of refrigerant gas lack

·

Cooler expansion valve (opened excessively)

·

DEF servo motor malfunction

·

Damper and link operation (jamming)



PROCEDURE

1.CHECK REFRIGERANT SHORTAGE
a.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Vehicle Condition Engine running
A/C Switch On
Ambient Temperature*1 0 to 49°C (32 to 120°F)
Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
Set Temperature MAX COLD
Recirculation/fresh Control Switch Recirculation
Air Vent Damper Position FACE
Blower Speed HI

HINT:

*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.



b.

Using the GTS, check the amount of refrigerant.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 4578
NOTICE:

If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.


HINT:
·

If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.

·

When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.



Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct
Refrigerant incorrect Incorrect


OK:

"Refrigerant correct" is displayed on the GTS.



Result:
Proceed to
OK
NG



OK

2.CHECK OPERATION

NG

2.CHECK OPERATION
a.

Check that the air conditioning system changes to DEF mode according to the switch operation, when the MODE switch on the air conditioning control assembly is pushed.

OK:

Air conditioning system changes to DEF mode.



Result:
Proceed to
OK
NG



OK

NG