Home › General › SPECIFICATIONS › HEATING / AIR CONDITIONING › 2021.04–2021.07
RM38G0E _V1 General _100727 SPECIFICATIONS _0467947 HEATING / AIR CONDITIONING F

SPECIFICATIONS  HEATING / AIR CONDITIONING  SERVICE DATA  


REFRIGERANT
Condenser Type Air Conditioning Type Cool Box Refrigerant Charging Amount
Refrigerant charge volume for Type A w/o Rear Cooler w/o Cool Box 690 to 750 g (24.3 to 26.5 oz)
w/ Cool Box 840 to 900 g (29.6 to 31.7 oz)
w/ Rear Cooler w/o Cool Box 840 to 900 g (29.6 to 31.7 oz)
w/ Cool Box 970 to 1030 g (34.2 to 36.3 oz)
for Type B w/o Rear Cooler w/ Cool Box 920 to 980 g (32.5 to 34.6 oz)
w/ Rear Cooler w/o Cool Box 920 to 980 g (32.5 to 34.6 oz)
w/ Cool Box 1040 to 1100 g (36.7 to 38.8 oz)

RELAY
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω