Home › Vehicle Exterior › MIRROR (EXT) › OUTER REAR VIEW MIRROR GLASS
RM38G0E _59 Vehicle Exterior _100827 MIRROR (EXT) _0468033 OUTER REAR VIEW MIRROR GLASS G

MIRROR (EXT)  OUTER REAR VIEW MIRROR GLASS  INSPECTION  


PROCEDURE

Hide 87961 1.INSPECT OUTER MIRROR LH (w/ Mirror Heater)

a.
B525821C01
1.313,1.125 1.813,1.125 true 1.302,1.583 1.802,1.583 true 0.167,0.073 0.479,0.229 0.313,0.156 10 false *a 1.177,1.063 1.49,1.219 0.313,0.156 10 false 1 1.177,1.521 1.49,1.677 0.313,0.156 10 false 2
*a Component without harness connected
(Outer Mirror LH)


Check the outer mirror heater operation.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 25°C (77°F) 3.9 to 5.3 Ω


If the result is not as specified, replace the outer mirror LH.



Hide 87931 2.INSPECT OUTER MIRROR RH (w/ Mirror Heater)

a.
B525823C01
1.667,1.583 2.167,1.583 false 1.667,1.115 2.167,1.115 false 2.26,1.052 2.417,1.25 0.156,0.198 10 false 1 2.26,1.5 2.417,1.698 0.156,0.198 10 false 2 0.354,0.375 0.667,0.573 0.313,0.198 10 false *a
*a Component without harness connected
(Outer Mirror RH)


Check the outer mirror heater operation.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 25°C (77°F) 3.9 to 5.3 Ω


If the result is not as specified, replace the outer mirror RH.



Hide 87961 3.INSPECT OUTER MIRROR LH (w/ Blind Spot Monitor System)

a.

Check the outer rear view mirror indicator operation.

i.

Connect 4 new 1.5 V dry-cell batteries in series.


ii.
B607292C03
0.104,0.063 0.417,0.219 0.313,0.156 10 false *a
*a Component without harness connected
(Outer Mirror LH)


Apply 6 V dry-cell batteries to the terminals of the connector, and check the blind spot monitor indicator condition.

NOTICE:
·

Do not use rechargeable batteries as they may not output a voltage of 1.5 V.

·

Do not apply a voltage of higher than 6 V.



OK:
Tester Connection Specified Condition
Positive (+) end of the 6 V dry-cell battery → 2
Negative (-) end of the 6 V dry-cell battery → 3
Outer rear view mirror indicator comes on


If the result is not as specified, replace the outer mirror LH.



Hide 87931 4.INSPECT OUTER MIRROR RH (w/ Blind Spot Monitor System)

a.

Check the outer rear view mirror indicator operation.

i.

Connect 4 new 1.5 V dry-cell batteries in series.


ii.
B607293C02
0.052,0.083 0.365,0.24 0.313,0.156 10 false *a
*a Component without harness connected
(Outer Mirror RH)


Apply 6 V dry-cell batteries to the terminals of the connector, and check the blind spot monitor indicator condition.

NOTICE:
·

Do not use rechargeable batteries as they may not output a voltage of 1.5 V.

·

Do not apply a voltage of higher than 6 V.



OK:
Tester Connection Specified Condition
Positive (+) end of the 6 V dry-cell battery → 2
Negative (-) end of the 6 V dry-cell battery → 3
Outer rear view mirror indicator comes on


If the result is not as specified, replace the outer mirror RH.



Hide 87961 5.INSPECT OUTER MIRROR LH (w/ EC Mirror)

a.

Check EC mirror operation.

i.

Connect a new 1.5 V dry-cell battery.


ii.
B607292C01
0.104,0.063 0.417,0.219 0.313,0.156 10 false *a
*a Component without harness connected
(Outer Mirror LH)


Apply 1.5 V dry-cell battery to the terminals of the connector, and check that the EC mirror operation.

NOTICE:

Do not apply a voltage of higher than 1.5 V.


OK:
Tester Connection Specified Condition
Positive (+) end of the 1.5 V dry-cell battery → 4
Negative (-) end of the 1.5 V dry-cell battery → 1
Mirror surface becomes dark


If the result is not as specified, replace the outer mirror LH.



Hide 87931 6.INSPECT OUTER MIRROR RH (w/ EC Mirror)

a.
B607293C01
0.052,0.083 0.365,0.24 0.313,0.156 10 false *a
*a Component without harness connected
(Outer Mirror RH)


Check EC mirror operation.

i.

Connect a new 1.5 V dry-cell battery.


ii.

Apply 1.5 V battery voltage to the terminals of the connector, and check that the EC mirror operation.

NOTICE:

Do not apply a voltage of higher than 1.5 V.


OK:
Tester Connection Specified Condition
Positive (+) end of the 1.5 V dry-cell battery → 4
Negative (-) end of the 1.5 V dry-cell battery → 1
Mirror surface becomes dark