Home › Steering › STEERING COLUMN › POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM
RM38G0E _55 Steering _100923 STEERING COLUMN _0468603 POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM U

STEERING COLUMN  POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM  TERMINALS OF ECU  


MULTIPLEX TILT AND TELESCOPIC ECU


C376767C25
3.365,0.042 3.781,0.281 0.417,0.24 0.104,0.094 0.417,0.292 0.313,0.198 10 false *a 3.5,0.094 4.094,0.354 0.594,0.26 10 false I43
*a Component with harness connected
(Multiplex Tilt and Telescopic ECU)
- -


a.

Measure the voltage and resistance according to the value(s) in the table below.

HINT:

Inspect the connectors from the back side while the connectors are connected.


Terminal No. (Symbol) Terminal Description Condition Specified Condition
I43-1 (GND) - Body ground ECU ground Always Below 1 Ω
I43-2 (+B) - I43-1 (GND) Motor power source Ignition switch off 11 to 14 V
I43-3 (CANP) - I43-11 (CANN) CAN communication Ignition switch off 54 to 69 Ω
I43-4 (E1) - Body ground Tilt sensor ground Always Below 1 Ω
I43-5 (VC) - I43-18 (MSW) Tilt and telescopic switch signal Ignition switch ON 4.9 to 5.1 V
I43-6 (TEM+) - I43-1 (GND) Telescopic motor output
·

Ignition switch ON

·

Steering column contracting


11 to 14 V
Telescopic motor not operating Below 1 V
I43-7 (TIM+) - I43-1 (GND) Tilt motor output
·

Ignition switch ON

·

Steering wheel tilting up


11 to 14 V
Tilt motor not operating Below 1 V
I43-8 (GND2) - Body ground ECU ground Always Below 1 Ω
I43-9 (ECUB) - I43-1 (GND) ECU power source Ignition switch off 11 to 14 V
I43-10 (IG) - I43-1 (GND) IG signal / IG power source Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
I43-13 (VCI) - I43-4 (E1) Tilt sensor power source Ignition switch ON 8 to 14 V
I43-14 (VCE) - I43-17 (E2) Telescopic sensor power source Ignition switch ON 8 to 14 V
I43-15 (TES) - I43-17 (E2) Telescopic sensor signal Telescopic motor operating Pulse generation
HI: 8 to 14 V
LOW: Below 1 V
I43-16 (TIS) - I43-4 (E1) Tilt sensor signal Tilt motor operating Pulse generation
HI: 8 to 14 V
LOW: Below 1 V
I43-17 (E2) - Body ground Telescopic sensor ground Always Below 1 Ω
I43-19 (TEM-) - I43-1 (GND) Telescopic motor output
·

Ignition switch ON

·

Steering column extending


11 to 14 V
Telescopic motor not operating Below 1 V
I43-20 (TIM-) - I43-1 (GND) Tilt motor output
·

Ignition switch ON

·

Steering wheel tilting down


11 to 14 V
Tilt motor not operating Below 1 V