INSTALL CUSTOMIZE THEFT DETERRENT SYSTEM
The following items can be customized.
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
Customizing with the GTS.
Select the setting by referring to the table below.
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Security Control with Mechanism Key Function | This function makes it possible to cancel the security alarm with the mechanical key. | Disable | $00:Disable,$01:Enable | Main Body ECU (Multiplex Network Body ECU) |
| Intrusion Sensor Sound Detection Function | Set to detect an intrusion using the sound detection function.* | Enable | $00:Disable,$01:Enable | Main Body ECU (Multiplex Network Body ECU) |
| Intrusion Sensor Reduction in Sensitivity Setting | This function adjusts sensitivity of the sensor that detects intrusions.* | Enable | $00:Enable,$01:Disable | Main Body ECU (Multiplex Network Body ECU) |
*: w/ Intrusion Sensor Cancel Switch
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Panic Function | This function operates the theft deterrent system by continuously pressing the panic switch on the electrical key transmitter sub-assembly for 0.8 seconds* | Enable | $00:Disable,$01:Enable | Main Body ECU (Multiplex Network Body ECU) |
*: w/ Panic Switch
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Window Open Warning Function | This function is used to enable or disable the window open warning. | Enable | $00:Disable,$01:Enable | Main Body ECU (Multiplex Network Body ECU) |
| Slide Roof Open Warning Function | This function is used to enable or disable the sliding roof open warning.* | Enable | $00:Disable,$01:Enable | Main Body ECU (Multiplex Network Body ECU) |
*: w/ Sliding Roof System