Home › Drivetrain › AC60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY
RM38G0E _52 Drivetrain _100436 AC60F AUTOMATIC TRANSMISSION / TRANSAXLE _0468719 VALVE BODY ASSEMBLY G

AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35210A 1.INSPECT SOLENOID(SL1) VALVE

a.
C197715C78
1.76,1.0 2.208,0.365 true 1.5,1.0 1.052,0.365 true 1.76,2.979 2.208,2.354 true 1.479,2.99 1.052,2.354 true 0.052,0.01 0.365,0.208 0.313,0.198 10 *a 2.24,0.198 2.406,0.396 0.167,0.198 10 1 0.917,0.198 1.083,0.396 0.167,0.198 10 2 2.24,2.188 2.406,2.385 0.167,0.198 10 1 0.917,2.188 1.083,2.385 0.167,0.198 10 2 1.927,3.927 2.156,4.125 0.229,0.198 10 (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 (-)
*a Component without harness connected
(Solenoid (SL1) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


If the value is not as specified, replace the solenoid (SL1) valve.


b.

Apply 12 V battery voltage to the solenoid (SL1) valve and check that the valve moves and makes an operating noise.

Standard:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the value is not as specified, replace the solenoid (SL1) valve.


Hide 35210C 2.INSPECT SOLENOID(SL2) VALVE

HINT:

Refer to Inspect solenoid (SL1) valve.


Hide 35210B 3.INSPECT SOLENOID(SL3) VALVE

HINT:

Refer to Inspect solenoid (SL1) valve.


Hide 35210D 4.INSPECT SOLENOID(SL4) VALVE

HINT:

Refer to Inspect solenoid (SL1) valve.


Hide 35280A 5.INSPECT SOLENOID(SLU) VALVE

HINT:

Refer to Inspect solenoid (SL1) valve.


Hide 35290C 6.INSPECT SOLENOID(SLT) VALVE

HINT:

Refer to Inspect solenoid (SL1) valve.


Hide 35240D 7.INSPECT SOLENOID(SL) VALVE

a.
C320237C07
0.083,0.063 0.396,0.26 0.313,0.198 10 false *a 2.542,1.448 3,1.646 0.458,0.198 10 false (+) 3.167,1.479 3.385,1.667 0.219,0.188 10 false (-)
*a Component without harness connected
(Solenoid (SL) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
solenoid (SL) valve connector terminal - solenoid (SL) valve body 20°C (68°F) 11 to 15 Ω


If the value is not as specified, replace the solenoid (SL) valve.


b.

Apply 12 V battery voltage to the solenoid (SL) valve and check that the valve moves and makes an operating noise.

Standard:
Measurement Condition Specified Condition
·

Battery positive (+) → solenoid (SL) valve connector

·

Battery negative (-) → solenoid (SL) valve body


Valve moves and makes an operating noise


If the value is not as specified, replace the solenoid (SL) valve.