AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  PARK / NEUTRAL POSITION SWITCH  INSPECTION  


PROCEDURE

Hide 84540 1.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

a.
C460265C01
1.5,0.125 1.917,0.375 0.417,0.25 1.083,1.656 1.208,1.656 1.208,1.656 1.354,1.292 true 2.375,1.615 2.219,1.615 2.219,1.615 2.094,1.281 true 1.365,1.885 1.51,1.885 1.51,1.885 1.708,1.292 true 1.823,0.958 2.042,0.5 2.042,0.5 2.167,0.5 true 1.583,0.958 1.344,0.375 1.344,0.375 1.208,0.375 true 1.26,0.958 1.104,0.635 1.104,0.635 0.969,0.635 true 2.292,1.854 2.156,1.854 2.156,1.854 1.969,1.281 true 0.896,1.583 1.156,1.792 0.26,0.208 10 false NL 2.448,1.531 2.813,1.729 0.365,0.198 10 false L 1.156,1.813 1.438,2.021 0.281,0.208 10 false DL 0.063,0.031 0.281,0.229 0.219,0.198 10 false *a 0.979,0.302 1.271,0.5 0.292,0.198 10 false RB 2.229,0.427 2.615,0.635 0.385,0.208 10 false RL 0.844,0.552 0.979,0.75 0.135,0.198 10 false B 2.365,1.771 2.656,1.969 0.292,0.198 10 false PL 1.583,0.167 2,0.333 0.417,0.167 10 false C34
*a Component without harness connected
(Park/Neutral Position Switch Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(C34)Location & Routing

Click Connector(C34)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>Park/Neutral Position Switch Assembly

C34-4 (B) - C34-5 (L) Shift lever in P or N Below 1 Ω
C34-2 (RB) - C34-6 (PL) Shift lever in P Below 1 Ω
C34-2 (RB) - C34-1 (RL) Shift lever in R Below 1 Ω
C34-2 (RB) - C34-9 (NL) Shift lever in N Below 1 Ω
C34-2 (RB) - C34-7 (DL) Shift lever in D, S, "+" or "-" Below 1 Ω
C34-4 (B) - C34-5 (L) Shift lever not in P or N 10 kΩ or higher
C34-2 (RB) - C34-6 (PL) Shift lever not in P 10 kΩ or higher
C34-2 (RB) - C34-1 (RL) Shift lever not in R 10 kΩ or higher
C34-2 (RB) - C34-9 (NL) Shift lever not in N 10 kΩ or higher
C34-2 (RB) - C34-7 (DL) Shift lever not in D, S, "+" or "-" 10 kΩ or higher


If the resistance value is not as specified, replace the park/neutral position switch assembly.