1GR-FE BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


C458640N01
2.229,0.281 2.615,0.542 0.385,0.26 5.427,0.281 5.813,0.542 0.385,0.26 2.302,0.333 2.615,0.542 0.313,0.208 10 false C92 5.542,0.333 5.854,0.542 0.313,0.208 10 false B2

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Terminal Description Condition Specified Condition
B2-1 (BATT) - C92-81 (E1) Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
C92-81 (E1) - Body ground Ground Always Below 1 Ω
C92-25 (LIN) - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher