The rear blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly.
If the airflow volume is low or the blower speed cannot be changed, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| Airflow volume cannot be changed |
·
Air conditioning amplifier assembly malfunction
·
Rear blower motor with fan sub-assembly malfunction
·
Blower motor control malfunction
·
Harness or connector |
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Blower Level | Rear blower motor with fan sub-assembly operation | 0 to 31 | - |
| Tester Display |
|---|
| Rear Blower Level |
| Result | Proceed to |
|---|---|
| Rear blower motor with fan sub-assembly does not operate | A |
| Rear blower motor with fan sub-assembly operates but does not change speed | B |
A
B
| *a | Front view of wire harness connector (to No. 1 Cooler Wiring Harness Sub-assembly) |
Disconnect the No. 1 cooler wiring harness sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 1 cooler wiring harness sub-assembly connector.
Disconnect the I31 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I31)Location & Routingewd_type=routing;type=c;code=I31 |
||
| 8 - I31-10 (SBLW) | Always | Below 1 Ω |
| 8 or I31-10 (SBLW)- Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I31 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I31)Location & Routingewd_type=routing;type=c;code=I31 |
||
| I31-10 (SBLW) - Body ground | Always | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the No. 1 cooler wiring harness sub-assembly with a new or known good one and check that the condition returns to normal.
Same problem does not occur.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected (Blower Motor Control) |
Using an oscilloscope, check the waveform.
| Tester Connection | Tool Setting | Condition |
|---|---|---|
Click Location & Routing(Q75)Location & Routingewd_type=routing;type=c;code=Q75 |
||
| Q75-3 - Body ground | 1 V/DIV., 500 μs./DIV. |
·
Ignition switch ON
·
Blower speed: LO |
The waveform varies with the blower speed.
Waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the blower motor control with a new or known good one and check that the condition returns to normal.
Same problem does not occur.
| Proceed to |
|---|
| OK |
| NG |
OK
NG