FREEZE FRAME DATA
It is difficult to show the specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specification.
Turn the ignition switch to ON and park the vehicle on level ground. Check the freeze frame data by using the GTS.
Display the DTCs on the DTC check screen.
Check the freeze frame data on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Total distance traveled | Min.: 0, Max.: 16777215 | - | - |
| Total Distance Traveled - Unit | Total Distance Traveled unit | km/mile | - | - |
| Steering Angle Velocity (PPS) | Steering angle speed | Min.: 0 deg/s Max.: 6000 deg/s |
Value changes in proportion to steering effort: Engine running and steering wheel being turned | - |
| Steering Angle (PPS) | Steering angle | Min.: -3072.0 deg Max.: 3070.5 deg |
Engine running and steering wheel being turned
·
Left turn: Increases
·
Right turn: Decreases |
- |
| Solenoid Actual Current (PPS) | Solenoid current | Min.: 0 mA Max.: 1000 mA |
200 to 950 mA: Engine running and steering wheel being turned | - |
| IG Power Supply (PPS) | ECU power source voltage | Min.: 0.0 V Max.: 25.5 V |
11 to 14 V: The ignition switch ON | - |
| Vehicle Speed (PPS) | Vehicle speed from meter | Min.: 0.00 km/h (0.00 mph) Max.: 327.67 km/h (203.61 mph) |
0 km/h (0 mph): Vehicle stopped No large fluctuation: Vehicle driven at a constant speed |
- |
| Engine Revolution (PPS) | Engine speed | Min.: 0 rpm Max.: 12800 rpm |
No large fluctuation: Engine running at a constant speed | - |
| MAP Information (PPS) | Number of DTCs | Min.: 0 Max.: 255 |
0 | - |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Total distance traveled | Min.: 0, Max.: 16777215 | - | - |
| Total Distance Traveled - Unit | Total Distance Traveled unit | km/mile | - | - |
| PPS Failure Information | Hydraulic power steering system failure information | Normal/Invalid/Failure | - | - |
| Vehicle Speed | Vehicle speed from speedometer | Min.: 0.0 km/h (0.0 mph) Max.: 300.0 km/h (186.4 mph) |
·
0 km/h (0 mph): Engine running and vehicle stopped
·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Engine Revolution | Engine speed | Min.: 0 rpm Max.: 12800 rpm |
No significant fluctuation | Engine running at a constant speed |
| Battery Voltage | Battery voltage | Min.: 0.00 V Max.: 25.00V |
11 to 14 V | - |
| Steering Wheel Torque | Steering wheel torque | Min.: -25.000 Nm Max.: 25.001 Nm |
Value changes in proportion to steering effort - The value increases when turning left and decreases when turning right |
Engine running and steering wheel being turned |
| Steering Angle Velocity | Steering angle speed | Min.: -32768 deg/s Max.: 32767 deg/s |
Value changes in proportion to steering effort - The value increases when turning left and decreases when turning right |
Engine running and steering wheel being turned |
| Steering Angle | Steering angle | Min.: -3072.0 deg Max.: 3070.5 deg |
- | - |
| Status of Vehicle Power (IGP PT2) | State of IGP power source(PT2) | OFF or ON | OFF: Ignition switch off ON: Ignition switch ON |
- |
| Status of Vehicle Power (IGP PT1) | State of IGP power source(PT1) | OFF or ON | OFF: Ignition switch off ON: Ignition switch ON |
- |
| Status of Vehicle Power (IGP PDC) | State of IGP power source(PDC) | OFF or ON | OFF: Ignition switch off ON: Ignition switch ON |
- |
| Status of Vehicle Power (IGR PDC) | State of IGR power source(PDC) | OFF or ON | OFF: Ignition switch off ON: Ignition switch ON |
- |
| IG Power Supply | IG power source voltage | Min.: 0.00 V Max.: 25.00V |
8 to 16 V*1 10.5 to 16 V*2 |
Ignition switch ON |
| PIG Power Supply | PIG power source voltage | Min.: 0.00 V Max.: 25.00 V |
9 to 16 V | Engine running and steering wheel being turned |
| Thermistor Temperature | ECU substrate temperature | Min.: -50.0°C (-58.0°F) Max.: 200.0 °C (392.0 °F) |
-50°C to 200°C (-58°F to 392°F) | - |
| Power Source | Operating state of hybrid system | Operating State or Stopped State | Operating State: Engine running Stopped State: Engine not started |
- |
| PS Assist Signal | Status of the record of power steering assist signal | Assist Stop or Under an Assist | Assist Stop: Ignition switch ON Under an Assist: Engine running |
- |
| Torque Sensor 1 Output | Torque sensor 1 output value | Min.: -25.000 Nm Max.: 25.001 Nm |
- | - |
| Torque Sensor 2 Output | Torque sensor 2 output value | Min.: -25.000 Nm Max.: 25.001 Nm |
- | - |
| Torque Sensor 3 Output | Torque sensor 3 output value | Min.: -25.000 Nm Max.: 25.001 Nm |
- | - |
| Torque Sensor 4 Output | Torque sensor 4 output value | Min.: -25.000 Nm Max.: 25.001 Nm |
- | - |
| Motor 1 U Phase Current | Motor 1 terminal current (U phase) | Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned |
| Motor 1 V Phase Current | Motor 1 terminal current (V phase) | Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned |
| Motor 1 W Phase Current | Motor 1 terminal current (W phase) | Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned |
| Motor 1 U Phase Duty | Motor 1 U phase duty | Min.: 0.00% Max.: 100.00% |
- | - |
| Motor 1 V Phase Duty | Motor 1 V phase duty | Min.: 0.00% Max.: 100.00% |
- | - |
| Motor 1 W Phase Duty | Motor 1 W phase duty | Min.: 0.00% Max.: 100.00% |
- | - |
| Motor 1 Power Supply | Power supply voltage to active motor 1 | Min.: 0.00 V Max.: 25.00 V |
9 to 16 V | Engine running and steering wheel being turned |
| Motor 2 U Phase Current | Motor 2 terminal current (U phase) | Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned |
| Motor 2 V Phase Current | Motor 2 terminal current (V phase) | Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned |
| Motor 2 W Phase Current | Motor 2 terminal current (W phase) | Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned |
| Motor 2 U Phase Duty | Motor 2 U phase duty | Min.: 0.00% Max.: 100.00% |
- | - |
| Motor 2 V Phase Duty | Motor 2 V phase duty | Min.: 0.00% Max.: 100.00% |
- | - |
| Motor 2 W Phase Duty | Motor 2 W phase duty | Min.: 0.00% Max.: 100.00% |
- | - |
| Motor 2 Power Supply | Power supply voltage to active motor 2 | Min.: 0.00 V Max.: 25.00 V |
9 to 16 V | Engine running and steering wheel being turned |
| Motor Rotation Angle Sensor 1 Sin Voltage | Rotation angle sensor Sin1 output voltage used for rotation angle calculation | Min.: 0.00 V Max.: 5.00 V |
- | - |
| Motor Rotation Angle Sensor 1 Cos Voltage | Rotation angle sensor Cos1 output voltage used for rotation angle calculation | Min.: 0.00 V Max.: 5.00 V |
- | - |
| Motor Rotation Angle Sensor 2 Sin Voltage | Rotation angle sensor Sin2 output voltage used for rotation angle calculation | Min.: 0.00 V Max.: 5.00 V |
- | - |
| Motor Rotation Angle Sensor 2 Cos Voltage | Rotation angle sensor Cos2 output voltage used for rotation angle calculation | Min.: 0.00 V Max.: 5.00 V |
- | - |
| Motor Rotation Angle Sensor 3 Sin Voltage | Rotation angle sensor Sin3 output voltage used for rotation angle calculation | Min.: 0.00 V Max.: 5.00 V |
- | - |
| Motor Rotation Angle Sensor 3 Cos Voltage | Rotation angle sensor Cos3 output voltage used for rotation angle calculation | Min.: 0.00 V Max.: 5.00 V |
- | - |
| Motor Actual Current (Q Axis) | Detected current flow to motor (detected current of axis q) | Min.: -327.68 A Max.: 327.67 A |
- | - |
| Command Value Current (Q Axis) | Target current flow to motor (requested current of axis q) | Min.: -327.68 A Max.: 327.67 A |
- | - |
| Motor Actual Current 2 (D Axis) | Detected current flow to motor (detected current of axis d) | Min.: -327.68 A Max.: 327.67 A |
- | - |
| Command Value Current 2 (D Axis) | Target current flow to motor (requested current of axis d) | Min.: -327.68 A Min.: -327.68 A |
- | - |
| Motor Rotation Angle | Motor rotation angle (detected by rotation sensor) | Min.: 0.0 deg Max.: 360.1 deg |
During steering operation, motor rotation angle value changes from 0 to 360° | Engine running and steering wheel being turned |
| Final Motor Current Limited (Q Axis) | Final motor current set limit (request current of axis q) | Min.: 0.00 A Max.: 327.67 A |
- | - |
| Steering Angle Sensor Signal State | State of steering angle sensor signal | Usable/Unlearned/Sensor Fault/Communication Fault | - | - |
| CAN Vehicle Speed (Speed Sensor RR) | Speed sensor RR value sent via CAN | Min.: 0 km/h (0 mph) Max.: 255 km/h (158 mph) |
·
0 km/h (0 mph): Engine running and vehicle stopped
·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| CAN Vehicle Speed (Speed Sensor RL) | Speed sensor RL value sent via CAN | Min.: 0 km/h (0 mph) Max.: 255 km/h (158 mph) |
·
0 km/h (0 mph): Engine running and vehicle stopped
·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| CAN Vehicle Speed (SP1) | Vehicle speed input value sent via CAN (equal to value indicated on speedometer) | Min.: 0.0 km/h (0.0 mph) Max.: 300.0 km/h (186.4 mph) |
·
0 km/h (0 mph): Engine running and vehicle stopped
·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| CAN Steering Angle Speed (SSAV) | Steering wheel turning speed value sent via CAN | Min.: -32768 deg/s Max.: 32767 deg/s |
- | - |
| Control State Information | Control state information | Min.: 0 Max.: 65535 |
- | - |
| ASIC State Information | ASIC state information | Min.: 0 Max.: 65535 |
- | - |
| ECU Overheat Prevention Part | Internal component of ECU for which overheat protection control is performed | No Target Part/IPWM/Inverter MOS/Power Supply Relay MOS/Custom IC/Choke Coil/H Bridge MOS/Motor Relay MOS | - | - |
| ECU Estimate Temperature of Overheat Prevention Part | Estimated temperature of internal component of ECU for which overheat protection control is performed | -50.0°C (-58.0°F) to 200.1 °C (392.2 °F)/Unknown | - | - |
| Motor Overheat Prevention Part | Internal component of motor for which overheat protection control is performed | No Target Part/Motor | - | - |
| Motor Estimate Temperature of Overheat Prevention Part | Estimated temperature of internal component of motor for which overheat protection control is performed | -50.0°C (-58.0°F) to 200.1 °C (392.2 °F)/Unknown | - | - |
*1: w/o Stop and Start System