The cooler thermistor (duct sensor) (for LH Side) is installed in the rear quarter trim board to detect the rear room temperature, which is used to control the air conditioning system. The resistance of the cooler thermistor (duct sensor) (for LH Side) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies voltage (5 V) to the cooler thermistor (duct sensor) (for LH Side) and reads voltage changes due to changes in the resistance of the cooler thermistor (duct sensor) (for LH Side).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B147A15 | Rear Left Room Temperature Sensor Circuit Short to Battery or Open | Diagnosis Condition: Ignition switch ON Malfunction Status: Open or short to +B in rear room temperature sensor LH circuit Detection Time: Continuously for 4 seconds or more |
·
Cooler thermistor (duct sensor) (for LH Side)
·
Harness or connector
·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ○ | ○ |
| Malfunction Status | Open in rear room temperature sensor LH circuit | ○ | - |
| Short to +B in rear room temperature sensor LH circuit | - | ○ | |
| Detection Time | Continuously for 4 seconds or more | Continuously for 4 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
Pre-procedure1
Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
Click Location & Routing(U1)Location & Routingewd_type=routing;type=c;code=U1 Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LHewd_type=component;type=c;code=U1;pinno=1 |
||
| U1-1 - Body ground | Ignition switch ON | 0 to 5.5 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.
Connect terminals 1 and 2 of the cooler thermistor (duct sensor) (for LH Side) connector on the wire harness side.
| *1 | Cooler Thermistor (Duct Sensor) (for LH Side) | *2 | Air Conditioning Amplifier Assembly |
| *a | Front view of wire harness connector (to Cooler Thermistor (Duct Sensor) (for LH Side)) |
- | - |
Procedure1
According to the display on the GTS, read the Data List.
| Tester Display |
|---|
| Rear Left Room Temperature Sensor |
| GTS Display | Specified Condition |
|---|---|
| Rear Left Room Temperature Sensor | 327.67°C (621.81°F) |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR (for Rear Side)>REMOVAL
NG
Pre-procedure1
Disconnect the I30 air conditioning amplifier assembly connector.
Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I30,U1)Location & Routingewd_type=routing;type=c,c;code=I30,U1 Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LHewd_type=component;type=c;code=U1;pinno=1,2 |
||
| I30-10 (RLTR) - U1-1 | Always | Below 1 Ω |
| I30-14 (SG-8) - U1-2 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the I30 air conditioning amplifier assembly connector.
Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I30,U1)Location & Routingewd_type=routing;type=c,c;code=I30,U1 Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LHewd_type=component;type=c;code=U1;pinno=1 |
||
| I30-10 (RLTR) or U1-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG