Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM38G0E _58 Vehicle Interior _100766 HEATING / AIR CONDITIONING _0467925 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B147A15  Rear Left Room Temperature Sensor Circuit Short to Battery or Open  


DESCRIPTION

The cooler thermistor (duct sensor) (for LH Side) is installed in the rear quarter trim board to detect the rear room temperature, which is used to control the air conditioning system. The resistance of the cooler thermistor (duct sensor) (for LH Side) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies voltage (5 V) to the cooler thermistor (duct sensor) (for LH Side) and reads voltage changes due to changes in the resistance of the cooler thermistor (duct sensor) (for LH Side).

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
B147A15 Rear Left Room Temperature Sensor Circuit Short to Battery or Open Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Open or short to +B in rear room temperature sensor LH circuit


Detection Time:

Continuously for 4 seconds or more


·

Cooler thermistor (duct sensor) (for LH Side)

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized Air Conditioner A

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Status Open in rear room temperature sensor LH circuit ○ -
Short to +B in rear room temperature sensor LH circuit - ○
Detection Time Continuously for 4 seconds or more Continuously for 4 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored.


WIRING DIAGRAM

E368742E80
0.313,1.802 0.646,2 0.333,0.198 10 false U1 0.302,1.969 2.302,2.344 2,0.375 10 false Cooler Thermistor (Duct Sensor) (for LH Side) 4.635,1.792 4.969,1.99 0.333,0.198 10 false I30 4.635,1.948 7.125,2.135 2.49,0.188 10 false Air Conditioning Amplifier Assembly 2.146,0.667 2.323,0.885 0.177,0.219 10 false 1 2.156,1.156 2.333,1.375 0.177,0.219 10 false 2 4.521,1.135 4.792,1.344 0.271,0.208 10 false 14 4.531,0.656 4.781,0.906 0.25,0.25 10 false 10 4.813,0.667 5.24,0.854 0.427,0.188 10 false RLTR 4.833,1.146 5.24,1.333 0.406,0.188 10 false SG-8 5.656,0.271 5.948,0.469 0.292,0.198 11 false 5 V 6.302,0.792 6.552,0.979 0.25,0.188 10 false IC

PROCEDURE

1.CHECK COOLER THERMISTOR (DUCT SENSOR) (for LH Side) CIRCUIT

Pre-procedure1

a.

Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.


Procedure1

b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition

Click Location & Routing(U1)Location & Routing

Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LH

U1-1 - Body ground Ignition switch ON 0 to 5.5 V


Result:
Proceed to
OK
NG



Post-procedure1

c.

None



OK

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

NG

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR (DUCT SENSOR) (for LH Side))
2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

Pre-procedure1

a.

Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.


b.

Connect terminals 1 and 2 of the cooler thermistor (duct sensor) (for LH Side) connector on the wire harness side.

E446844C07
4.427,1.271 4.844,1.51 0.417,0.24 1.094,2.042 1.417,2.344 0.323,0.302 10 false *1 3.104,2.031 3.427,2.333 0.323,0.302 10 false *2 4.802,0.531 5.125,0.833 0.323,0.302 10 false *a 2.427,1.01 3.052,1.24 0.625,0.229 10 false RLTR 2.448,1.417 3.063,1.771 0.615,0.354 10 false SG-8 4.552,1.302 5.167,1.656 0.615,0.354 10 false U1
*1 Cooler Thermistor (Duct Sensor) (for LH Side) *2 Air Conditioning Amplifier Assembly
*a Front view of wire harness connector
(to Cooler Thermistor (Duct Sensor) (for LH Side))
- -



Procedure1

c.

According to the display on the GTS, read the Data List.

Body Electrical > Air Conditioner > Data List
Tester Display
Rear Left Room Temperature Sensor
50003 450 114
OK:
GTS Display Specified Condition
Rear Left Room Temperature Sensor 327.67°C (621.81°F)


Result:
Proceed to
OK
NG



Post-procedure1

d.

None



OK

REPLACE COOLER THERMISTOR (DUCT SENSOR) (for LH Side)

NG

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR (DUCT SENSOR) (for LH Side))
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR (DUCT SENSOR) (for LH Side))

Pre-procedure1

a.

Disconnect the I30 air conditioning amplifier assembly connector.


b.

Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(I30,U1)Location & Routing

Click Connector(I30)Instrument Panel>Instrument Panel Wire / Mobile Wireless Charger Cord / No. 1 Navigation Wire / No. 2 Instrument Panel Wire / No. 5 Instrument Panel Wire / Telephone Computer Wire>Air Conditioning Amplifier Assembly

Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LH

I30-10 (RLTR) - U1-1 Always Below 1 Ω
I30-14 (SG-8) - U1-2 Always Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

d.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR (DUCT SENSOR) (for LH Side))

Pre-procedure1

a.

Disconnect the I30 air conditioning amplifier assembly connector.


b.

Disconnect the U1 cooler thermistor (duct sensor) (for LH Side) connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(I30,U1)Location & Routing

Click Connector(I30)Instrument Panel>Instrument Panel Wire / Mobile Wireless Charger Cord / No. 1 Navigation Wire / No. 2 Instrument Panel Wire / No. 5 Instrument Panel Wire / Telephone Computer Wire>Air Conditioning Amplifier Assembly

Click Connector(U1)Body>No. 2 Room Wire>Cooler (Room Temperature Sensor) Thermistor Rear LH

I30-10 (RLTR) or U1-1 - Other terminals and body ground Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

d.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR