17650G 1.INSPECT PURGE VSV (DUTY VACUUM SWITCHING VALVE)
| *a | Component without harness connected (Purge VSV (Duty Vacuum Switching Valve)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C44)Location & Routingewd_type=routing;type=c;code=C44 |
||
| C44-1 - C44-2 | 20°C (68°F) | 23 to 26 Ω |
| C44-1 - Body ground | Always | 10 MΩ or higher |
| C44-1 - Body ground | Always | 10 MΩ or higher |
When measuring the coil resistance make sure that the surface temperature of the purge VSV (duty vacuum switching valve) is 20°C (68°F).
If the result is not as specified, replace the purge VSV (duty vacuum switching valve).
| *a | Port E |
| *b | Port F |
| *c | Port G |
| *d | Air |
Apply auxiliary battery voltage between the terminals of the purge VSV (duty vacuum switching valve) and check that the following occurs when blowing air into the port E.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C44)Location & Routingewd_type=routing;type=c;code=C44 |
||
| C44-1 - C44-2 | Battery voltage applied between the terminals | Air flows from port F and port G |
| Battery voltage not applied between the terminals | Air does not flow | |
If the result is not as specified, replace the purge VSV (duty vacuum switching valve).
Install a clean hose to the purge VSV (duty vacuum switching valve).
Check the operation of the duty vacuum switching valve.
Do not suck air through the purge VSV (duty vacuum switching valve).
Petroleum substances inside the purge VSV (duty vacuum switching valve) are hazardous to your health.
| *a | Clean Hose |
| *b | Air |
Blow air into the port E and check that air passes through easily.
If the result is not as specified, replace the purge VSV (duty vacuum switching valve).
| *a | Clean Hose |
| *b | Air |
Blow air into the port F and check that air passes through with difficulty.
If the result is not as specified, replace the purge VSV (duty vacuum switching valve).
| *a | Clean Hose |
| *b | Air |
Blow air into the port G and check that air passes through with difficulty.
If the result is not as specified, replace the purge VSV (duty vacuum switching valve).