The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced when repairing air leaks in the intake system are shown below.
When working near the engine room while the engine has started or the power source mode is ignition switch ON, do not touch the fan and generator V belt or rotating components such as the fan, etc.
Touching the fan and generator V belt or rotating components such as the fan, etc. could result in your hand or clothing getting caught and pulled in.
1.INSPECT INTAKE SYSTEM
Perform "Inspection After Repair" after repairing vacuum leaks in the intake system.
Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
Check that there are no vacuum leaks at the points shown in the illustration.
2.PERFORM INITIALIZATION
Perform "Inspection After Repair" after repairing vacuum leaks in the intake system.
Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION