17670B 1.INSPECT AIR BY-PASS VALVE ASSEMBLY
Disconnect the air by-pass valve assembly connector.
| *a | Component without harness connected (Air By-pass Valve Assembly) |
When applying battery voltage to the air by-pass valve assembly connector, check for an operating sound from the air by-pass valve assembly.
Check for an operating sound from the air by-pass valve assembly.
Inspect for a short time (10 seconds or less).
Make sure to perform switching from the battery terminal side.
If the plunger does not make an operating sound, replace the air by-pass valve assembly.
Connect the air by-pass valve assembly connector.