Home › Engine / Hybrid System › 1GR-FE (EMISSION CONTROL) › CANISTER
RM38G0E _51 Engine / Hybrid System _101531 1GR-FE EMISSION CONTROL _0470511 CANISTER G

1GR-FE EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 77720H 1.INSPECT FUEL OUTLET VALVE ASSEMBLY

a.

Visually check the charcoal canister assembly for cracks or damage.

If cracks or damage is found, replace the fuel outlet valve assembly.


b.

Check charcoal canister assembly air flow.

i.
A477973C01
1.063,1.604 0.76,1.938 0.76,1.938 0.604,1.938 true 2,1.438 1.76,1.969 1.76,1.969 1.604,1.969 true 2.917,1.219 2.677,1.75 2.677,1.75 2.521,1.75 true 2.292,1.656 2.51,1.813 0.219,0.156 10 false *a 1.354,1.896 1.552,2.052 0.198,0.156 10 false *b 0.385,1.875 0.583,2.031 0.198,0.156 10 false *c
*a Port A
*b Port B
*c Port C


Using a vacuum pump, check that air flows through the fuel outlet valve assembly according to the table below.

Standard:
Condition Specified Condition
Block port B and apply 2 kPa (15 mmHg, 0.591 in.Hg) of vacuum into port A There are no leaks
Apply 2 kPa (15 mmHg, 0.591 in.Hg) of vacuum into port A Air is sucked into port B
Blow 8 kPa (0.1 kgf/cm2, 1.2 psi) of air into port A Air comes out of port B
Block port B and apply 2 kPa (15 mmHg, 0.591 in.Hg) of vacuum into port C There are no leaks
Blow 8 kPa (0.1 kgf/cm2, 1.2 psi) of air into port C Air comes out of port B


If the result is not as specified, replace the fuel outlet valve assembly.



Hide 77740 2.INSPECT CHARCOAL CANISTER ASSEMBLY

a.

Visually check the charcoal canister assembly for cracks or damage.

If cracks or damage is found, replace the charcoal canister assembly.


b.

Inspect the airflow of the charcoal canister assembly.

i.
A477974C01
0.583,0.865 0.76,0.865 0.76,0.865 1.188,1.427 true 2.229,1.146 2.76,1.146 true 0.781,0.479 0.958,0.479 0.958,0.479 1.646,1.281 true 0.385,0.75 0.583,0.958 0.198,0.208 10 false *a 0.573,0.385 0.792,0.583 0.219,0.198 10 false *b 2.813,1.042 3.01,1.25 0.198,0.208 10 false *c 1.24,0.323 1.438,0.542 0.198,0.219 10 false *d
*a Port A
*b Port B
*c Port C
*d Air


Close the port A and check that air flows from the port C when air is blown into the port B.

OK:

The air flows out from the port C.


If the result is not as specified, replace the charcoal canister assembly.


ii.
A477975C01
0.417,0.917 0.625,0.917 0.625,0.917 1.198,1.448 true 2.219,1.135 2.813,1.135 true 1.042,0.229 1.25,0.229 1.25,0.229 1.677,1.25 true 0.198,0.833 0.417,1.063 0.219,0.229 10 false *a 0.844,0.146 1.052,0.354 0.208,0.208 10 false *b 2.885,1.042 3.115,1.25 0.229,0.208 10 false *c 0.802,0.427 1.01,0.635 0.208,0.208 10 false *d
*a Port A
*b Port B
*c Port C
*d Air


Close the port B and check that air flows from the port C when air is blown into the port A.

OK:

The air flows out from the port C.


If the result is not as specified, replace the charcoal canister assembly.



Hide 77740 3.CLEAN CHARCOAL CANISTER ASSEMBLY

a.
A477976C01
0.375,0.844 0.573,0.844 0.573,0.844 1.208,1.375 true 2.229,1.125 2.833,1.125 true 0.958,0.156 1.156,0.156 1.156,0.156 1.698,1.25 true 0.135,0.75 0.344,0.948 0.208,0.198 10 false *a 0.74,0.083 0.958,0.292 0.219,0.208 10 false *b 2.896,1.042 3.104,1.24 0.208,0.198 10 false *c 0.781,0.469 0.99,0.656 0.208,0.188 10 false *d
*a Port A
*b Port B
*c Port C
*d Air


Clean the filter by blowing 10 kPa (0.1 kgf/cm2, 1.5 psi) of compressed air into the port A while holding the port B closed.

NOTICE:
·

Make sure to clean the filter using only air. Do not use gasoline or any other means.

·

Do not disassemble the charcoal canister assembly.