16031 1.INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT
The valve opening temperature is inscribed on the thermostat.
Immerse the thermostat in the water, then heat the water gradually.
Do not your hands into the water that has been heated for the inspection.
Touching the heated water could result in burns.
Check the valve opening temperature of the thermostat.
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the water inlet sub-assembly with thermostat.
| *a | Valve Lift |
Check the valve lift.
8.0 mm (0.315 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the water inlet sub-assembly with thermostat.
Check that the valve is fully closed when the thermostat is at low temperature (below 40°C (104°F)).